Artesyn reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or changes.
Face Plate ............. . 39 Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 8
List of Figures Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 9
19, provides a German translation of the chapter "Safety Notes". Abbreviations This document uses the following abbreviations: Abbreviation Definition AdvancedTCA Advanced Telecommunications Computing Architecture ATCA Advanced Mezzanine Card Application Programming Interface Block Transfer Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 10
Intelligent Platform Management Bus IPMC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface LVDS Low Voltage Differential Signal Media Access Control Management Information Base Mezzanine Management Controller Managed Object NEBS Network Equipment Building System Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 11
Used to emphasize a word Used for on-screen output and code related elements Screen or commands in body text Used to characterize user input and to separate it Courier + Bold from system output Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 12
Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury Indicates a property damage message No danger encountered. Pay attention to important information Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 13
Order No. Date Description 6806800H33D May 2016 Removed Declaration of Conformity. 6806800H33C May 2014 Rebranded to Artesyn. 6806800H33B December 2012 Updated Chapter 1, Standard Compliances, on page 6806800H33A September 2010 First edition Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 14
About this Manual About this Manual Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Artesyn intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete.
Seite 16
Changes or modifications not expressly approved by Artesyn could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements.
Seite 17
Therefore, only install it in or remove it from a powered system if the system itself supports hot swap or high availability and if the system documentation explicitly includes guidelines. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 18
Safety Notes Replacement/Expansion Only replace or expand components or system parts with those recommended by Artesyn. Otherwise, you are fully responsible for the impact on EMC or any possible malfunction of the product. Check the total power consumption of all components installed (see the technical specification of the respective components).
Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im Handbuch enthaltenen Informationen nicht garantieren. Falls Sie weitere Informationen benötigen sollten, wenden Sie sich bitte an die für Sie zuständige Geschäftsstelle von Artesyn. Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf ausschließlich für Anwendungen in der Telekommunikationsindustrie und im Zusammenhang...
Sicherheitshinweise Das Produkt wurde in einem Artesyn Standardsystem getestet. Es erfüllt die für digitale Geräte der Klasse A gültigen Grenzwerte in einem solchen System gemäß den FCC-Richtlinien Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen einen angemessenen Schutz vor Störstrahlung beim Betrieb des Produktes in Gewerbe- sowie Industriegebieten...
Betreiben Sie das Board nur innerhalb der angegebenen Grenzwerte für die relative Luftfeuchtigkeit und Temperatur. Stellen Sie vor dem Einschalten des Stroms sicher, dass sich auf dem Board kein Kondensat befindet. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
System Hot Swap oder High-Availability unterstützt und wenn die Systembeschreibung dies ausdrücklich erlaubt. Austausch/Erweiterung Verwenden Sie bei Austausch oder Erweiterung nur von Artesyn empfohlene Komponenten und Systemteile. Andernfalls sind Sie für mögliche Auswirkungen auf EMV oder Fehlfunktionen des Produktes voll verantwortlich.
IPMBs and accesses one Fabric Interface (FI) of the corresponding AdvancedTCA blade. The Centellis 2000 User Card-10GE module is intended to be used in a CENT-2000 chassis. The module when installed in the dedicated User Card slot provides uplink connectivity from the payload Ethernet fabric channel.
Seite 24
XAUI 10G Ethernet interface which is converted by the 10G User Card to a serial 10G Ethernet interface on an SFP+ module. Figure 1-1 Functional Block Diagram of the Centellis 2000 Chassis Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Introduction Hardware The following figure gives an overview about the main parts of the board. Figure 1-2 Overview Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 26
Introduction Figure 1-3 Block Diagram Functional Characteristics: Transceiver – BCM8706 10GE Serial-to-XAUI 10GBASE-LRM transceiver – Compliant to IEEE 802.3ae and IEEE 802.3aq Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
– Local power generation of +5.0V, +3.3V and +1.0V Power on reset generation and power supervision Standard Compliances The Centellis 2000 User Card-10GE, when installed in a compliant chassis, meets the following standards: Table 1-1 Standard Compliances Standard Description...
The product has been designed to meet the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) Directive 2011/65/EU. Ordering Information The table below shows the board's ordering information. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 29
Introduction For further details please contact your local Artesyn representative. Table 1-2 Ordering Information Order No. Name Description CENT-2000-UC-10GE CENT-2000 10GE USER CARD Centellis 2000 uplink card without SFPP MODULE Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 30
Introduction Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Chapter 2 Centellis 2000 User Card-10GE Hardware Overview The Centellis 2000 User Card-10GE is compliant to PICMG 3.0 R3.0 (AdvancedTCA). The shelf manager and hub board is equipped with two backplane connectors. Figure 2-1 Hardware To prevent connector damage the alignment pin offers a guide rail to the slot and a coding mechanism to ensure the installation of the board in the matching slot.
Handle switch and status LED interface to the face plate Power supply Payload Hardware The payload hardware of the Centellis 2000 User Card-10GE is always powered when power supply is present. The following interfaces are available: Fabric 2 ethernet interface to payload slot ...
Programmer’s Reference. Power Supply The Centellis 2000 User Card-10GE is powered by dual redundant -48 VDC to -60 VDC (rated voltage) from the backplane connector. The IPMC is powered by 3.4 V from the shelf manager part of the board via the backplane.
2.4.2 Power Supply Holdup The Centellis 2000 User Card-10GE complies with the requirements for board level voltage transients as described in chapter 4.1.4.3. of PICMG 3.0 (AdvancedTCA) specification. It satisfies the requirement of uninterrupted operation during a power failure of 5 ms.
Installing an SFP/SFP+ Module Procedure In order to install an SFP/SFP+ module, proceed as follows: 1. Slide the SFP/SFP+ module into the slot until it locks into position. 2. Remove the optical port plug. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 36
Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+ module. When no cable is connected, cover the port with an optical port plug. 3. Connect the network cable to the SFP/SFP+ module. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
1. Remove any connected cable from the SFP module. 2. Open the SFP/SFP+ latch. Note that the latch mechanism of your SFP/SFP+ module may be slightly different compared to the latch shown in the following figure. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
The face plate mounting holes of the board are connected to frame ground. An ESD strip according to the AdvancedTCA specification PICMG 3.0 R3.0 is provided at one edge of the PCB. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
The following LEDs can be found on the face plate of the board. OOS, OK and H/S are ATCA LEDs and can be controlled via IPMI. For more information, see the Centellis 2000 User Card-10GE: Control via IPMI Programmer’s Reference manual.
Sensors The IPMC functionality is based on the IPMI specification V1.5. The IPMI sensors on the Centellis 2000 User Card-10GE are shownTable 3-2. For further information, see the Centellis 2000 User Card-10 GE: Control via IPMI Programmer’s Reference.
Seite 41
Controls, Indicators and Connectors Table 3-2 Centellis 2000 User Card-10GE Specific Sensors (continued) Sensor Type Code Generate Event/ Reading Type Sensor Name Description Event Code PMD_LinkAlarm Monitor IC (26h) Loss of signal Reading Type failure (4) indication PMD_CDR_LOCK Monitor IC (26h)
Seite 42
Controls, Indicators and Connectors Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Chapter 4 Board Exchange Introduction This chapter describes how to install the Centellis 2000 User Card-10GE board and includes the following information: Before installation Installing the board in a shelf Starting up the board Removing the board ...
5-20 Hz at 0.01 g in target at a rate of 0.1 octave/minute. 20-200 Hz at -3.0 dB/octave platform) Random 5-20 Hz at 1 m /Sec Random 20-200 Hz at -3 dB/octave Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
US and Canada: -48 VDC Operating Voltage -39 VDC to -72 VDC US and Canada: -39 VDC to -60 VDC Input current 0.2 A Centellis 2000 User Card-10GE power 3.8 W maximum dissipation Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
To inspect the shipment, perform the following steps: 1. Verify that you have received all items of your shipment: Printed Safety Notes Centellis 2000 User Card-10GE Any optional items ordered Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Before touching boards or electronic components, make sure that you are working in an ESD-safe environment or wear ESD wrist straps. The board must only be operated in a shelf that is properly grounded. To install the board into an AdvancedTCA shelf, proceed as follows. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
The switched off blue LED indicates that the board is activated. 8. Attach cables to the front panel connectors as necessary. Removing the Board This section describes how to remove the board from an AdvancedTCA system. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
"extraction pending", so that the blue LED is still blinking. 6. Wait until the blue LED is illuminated. 7. Remove the board from the shelf using the extraction handles. Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
Seite 50
Board Exchange Centellis 2000 User Card-10GE Installation and Use (6806800H33D)
The publications listed below are referenced in this manual. You can obtain electronic copies of Artesyn Embedded Technologies - Embedded Computing publications by contacting your local Artesyn sales office. For released products, you can also visit our Web site for the latest copies of our product documentation.
Seite 52
Related Documentation Table A-2 Related Specifications (continued) Organization Document Title PICMG PICMG 3.0 Revision 3.0 Advanced TCA Base Specification http://www.picmg.org Service Availability Forum Service Availability Forum Hardware Platform Interface http://www.saforum.org SAI-HPI-A01.01 Centellis 2000 User Card-10GE Installation and Use (6806800H33D)