IMPORTANT SAFETY INSTRUCTIONS
WHEN INSTALLING OR USING AN ELECTRICAL APPLIANCE
BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
WARNING
Risk of electric shock! If casing is removed or handled improperly
the internal components of the fixture may cause harm or become
permanently damaged. Do not expose the internal mechanisms/
components of this fixture to moisture.
WARNING
FELV terminals marked "Risk of electric shock" are not safe to touch.
WARNING
Circuits connected to any FELV control terminal shall be insulated for
the LV supply voltage of the controlgear and any terminals connected
to the FELV circuit shall be protected against accidental contact.
1. All electrical installation and repair work should be carried out
by a qualified electrician in accordance with current local codes
or regulations.
2. Do not connect any DALI/1-10V/0-10V/PWM terminals to mains power.
DALI wires are NOT SELV and should never be considered safe to
touch. Basic level of isolation or better is required between DALI wires
and mains cabling.
3. When connecting to the lighting control system and 1-10V/0-10V/PWM
terminals, use double/reinforced insulated wires
4. Consult local and national accessibility codes and regulations for
relevant installation guidelines. This fixture should be installed with
appropriate fixings for the installation environment. Conformity and
compliance is the responsibility of the installer.
5. If any part of the fixture is not working as it should, has received a sharp
blow, has been dropped, damaged, left outdoors, or been in contact
with water, do not use and contact the Dyson Helpline.
6. CAUTION: Possibly hazardous optical radiation emitted from this
fixture. Do not stare at the light source. May be harmful to the eye.
The fixture should be positioned so that prolonged staring into the light
source at a distance closer than 0.6m is not expected.
7. Do not install or use with a damaged suspension cable. If the
suspension cable supplied is damaged it must be replaced by Dyson, its
service agent or similiarly qualified person in order to avoid a hazard.
8. This fixture is compatible with DALI/1-10V/0-10V/PWM compliant
control systems.
9. Use a dry, lint free cloth or compressed air (solvent and moisture free) to
clean the fixture. Ensure the fixture is switched off before cleaning.
10. Ensure no pipe work (gas, water, air) or electrical cables, wires or
ductwork are located directly behind the drilling/mounting area.
11. Check that the electrical supply corresponds to that shown on the rating
plate. If the fixture is connected to any electrical supply other than that
stated on the rating plate permanent damage or improper/unsafe
operation of the fixture may result.
12. The fixture must be earthed.
13. The fixture is designed for dry, internal location only. Operating
environment range 0°C (32°F) to 40°C (104°F) and 10-95% RH
non-condensing.
14. RISK OF FIRE - Required clearance from structural members and fire
elements: SCB = 0mm HCB = 0mm