AR
LAGOON
• ﳚﺐ ﺍﻷﺧﺬ ﺑﻌﲔ ﺍﻻﻋﺘﺒﺎﺭ ﻓﻘﺪﺍﻥ ﺍﳌﺴﺎﻓﺔ ﻭﺍﳉﻬﺪ ﻟﻠﺨﻂ ﺍﻟﻜﻬﺮﺑﺎﰄ ﺍﻟﺬﻱ ﺳﻴﴵﺐ ﺑﲔ ﺍﻟﻠﻮﺣﺔ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﰲ ﻣﺪﺧﻞ
.ﻣﲋﻟﲂ ﻭﺍﻟﴶﺎﻥ ﺍﻟﻜﻬﺮﺑﺎﰄ
.( ﻣﻘﻄﻌﻪ 4 ﱈ2 ﻋﲆ ﺍﻷﻗﻞ ﻭ23 ﺃﻣﺒﲑAntigron) • ﳚﺐ ﺍﺳﺘﺨﺪﺍﻡ ﰷﺑﻞ ﺃﻧﺘﻴﺠﺮﻭﻥ
.(• )ﳚﺐ ﺃﺧﺬ ﻣﻌﺎﻣﻼﺕ ﺍﻟﺘﺨﻔﻴﺾ ﺑﻌﲔ ﺍﻻﻋﺘﺒﺎﺭ ﺑﺸﲁ ﻣﺴﺘﻘﻞ
. ً • ﳚﺐ ﺃﻥ ﻳﻜﻮﻥ ﺍﳋﻂ ﺍﻟﻜﻬﺮﺑﺎﰄ ﺍﻟﺬﻱ ﺳﻴﺠﺮﻱ ﺗﻮﺻﻴﻞ ﺍﳉﻬﺎﺯ ﷷ ﰲ ﺍﻟﻠﻮﺣﺔ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺩﺍﺧﻞ ﺍﻟﺸﻘﺔ ﻣﻨﻔﺼﻼ
ﻭﳚﺐ ﺃﻥ ﻳﻜﻮﻥ ﻓﺎﺻﻠﻪ ﺍﻟﻜﻬﺮﺑﺎﰄ 04 ﺃﻣﺒﲑ. ﻭﳚﺐ ﺃﻻ ﻳﻜﻮﻥ ﻋﲆ ﻫﺬﺍ ﺍﳋﻂ ﺃﻱ ﲪﻞ ﺁﺧﺮ ﻛﻔﻴﺸﺔ ﺃﻭ ﻣﺼﺒﺎﺡ ﺃﻭ
.ﺃﻱ ﳾﺀ، ﻭﻟﻮ ﰷﻥ ﻫﻨﺎﻙ ﳾﺀ ﻣﻦ ﻫﺬﺍ ﺍﻟﻘﺒﻴﻞ ﳚﺐ ﺇﻟﻐﺎﺅﻩ
• ﰲ ﺍﳊﺎﻻﺕ ﺍﻟﱵ ﻻ ﳝﻜﻦ ﻓﳱﺎ ﳑﻜ ﻨ ً ﺎ ﲮﺐ ﺧﻂ ﻣﺒﺎﴍ ﻟﻠﴶﺎﻥ ﺍﻟﻜﻬﺮﺑﺎﰄ ﺍﻟﻔﻮﺭﻱ ﳝﻜﻦ ﲮﺐ ﺧﻂ ﻣﻦ ﺃﻗﺮﺏ
.ﻣﻨﻔﺬ )ﺻﻨﺪﻭﻕ( ﻛﻬﺮﺑﺎﰄ ﻟﻠﺤﲈﻡ ﺇﺫﺍ ﰷﻥ ﻣﺘﻮﺍﻓ ﻘ ً ﺎ ﻣﻊ ﻣﻌﺎﻳﲑ ﺍﳌﺮﺍﻓﻖ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺩﺍﺧﻞ ﺍﳌﺒﲎ
• ﻭﰲ ﻫﺬﻩ ﺍﳊﺎﻟﺔ ﳚﺐ ﺇﻟﻐﺎﺀ ﺍﻟﻔﻴﺸﺎﺕ ﺍﻷﺧﺮﻯ ﺍﳌﺮﺗﺒﻄﺔ ﲠﺬﺍ ﺍﳌﻨﻔﺬ ﺍﳌﴵﻮﺏ ﻣﻨﻪ ﺧﻂ ﻟﺘﺸﻐﻴﻞ ﺍﻟﴶﺎﻥ ﺍﻟﻜﻬﺮﺑﺎﰄ
.ﺍﻟﻔﻮﺭﻱ
.• ﳚﺐ ﺃﻥ ﻳﻜﻮﻥ ﻓﺎﺻﻞ ﺍﻟﻜﻬﺮﺑﺎﺀ ﺍﳌﻮﺻﻮﻝ ﲠﺬﺍ ﺍﳌﻨﻔﺬ 04 ﺃﻣﺒﲑ
3 ﱈ2 ﰲ ﺍﻷﻣﺎﻛﻦ ﺍﻟﱵ ﻻ ﺗﻮﺟﺪ ﲠﺎ ﻣﺮﺍﻓﻖ ﻛﻬﺮﺑﺎﺀx4 ( ﲟﻘﻄﻊAntigron) • ﳚﺐ ﺍﺳﺘﺨﺪﺍﻡ ﰷﺑﻞ ﺃﻧﺘﻴﺠﺮﻭﻥ
.ﻣﻨﺎﺳﺒﺔ، ﳈﺎ ﻳﻠﺰﻡ ﺗﻮﺻﻴﻞ ﺍﳌﺮﺍﻓﻖ ﺍﳌﻀﺒﻮﻁ ﺗﺄﺭﺿﳱﺎ ﺑﺸﲁ ﻣﻌﻴﺎﺭﻱ ﻣﺒﺎﴍﺓ ﺑﺎﻟﴶﺎﻥ ﺍﻟﻜﻬﺮﺑﺎﰄ ﺍﻟﻔﻮﺭﻱ
• ﺇﺫﺍ ﰷﻧﺖ ﻗﳰﺔ ﺍﻟﻔﺎﺻﻞ ﺍﻟﻜﻬﺮﺑﺎﰄ ﺍﻷﺳﺎﳼ ﺑﺎﻟﺸﻘﺔ ﻣﻨﺨﻔﻀﺔ، ﳚﺐ ﺗﻐﻴﲑﻩ ﺑﺂﺧﺮ ﳛﻤﻞ ﻗﳰﺔ ﻣﻼﲚﺔ ﲝﺴﺎﺏ ﻳﻘﻮﻡ
.ﺑﻪ ﻓﲏ ﻛﻬﺮﺑﺎﺀ ﻣﺪﺭﺏ
• ﺇﻥ ﻃﺮﻳﻘﺔ ﺗﻮﺣﻴﺪ ﺧﻂ ﺍﻟﺘﺄﺭﻳﺾ ﺍﳌﳧﻰ ﰲ ﺍﻷﺳﻮﺍﻕ ﺑﺎﻟﺘﺼﻔﲑ ﻭﻣﺎ ﺇﱃ ﺫﻟﻚ ﺑﺎﳋﻂ ﺍﶈﺎﻳﺪ ﻟﻴﺲ ﻣﻨﺎﺳ ﺒ ً ﺎ ﺑﺎﻟﻨﺴﺒﺔ
.ﻟﻌﻤﻠﻴﺔ ﺍﻟﺘﺄﺭﻳﺾ. ﻭﳚﺐ ﺃﻻ ﻳﻮﺻﻞ ﲠﺬﺍ ﺍﻟﻨﻮﻉ ﻣﻦ ﺍﳋﻄﻮﻁ ﺇﻃﻼ ﻗ ً ﺎ
• ﳚﺐ ﺃﻥ ﻳﻘﻮﻡ ﻓﲏ ﻛﻬﺮﺑﺎﺀ ﻣﺪﺭﺏ ﺑﻌﻤﻞ ﺍﻟﺘﻮﺻﻴﻞ ﺍﻟﻜﻬﺮﺑﺎﰄ ﻟﴶﺎﻥ ﺍﳌﺎﺀ ﺍﻟﻔﻮﺭﻱ ﺍﳌﺮﻛﺐ ﺑﺎﳌﺮﺍﻓﻖ ﺍﳌﴵﻮﺑﺔ ﻭﺗﺸﻐﻴﻠﻪ
.ﻟﳭﺮﺓ ﺍﻷﻭﱃ
• ﻗﺒﻞ ﲻﻞ ﺍﻟﺘﻮﺻﻴﻼﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺩﺍﺧﻞ ﺍﶵﺎﻡ ﲜﻬﺎﺯﰼ ﳚﺐ ﲻﻞ ﺗﻮﺻﻴﻠﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺑﲔ ﺍﳉﻬﺎﺯ ﻭﺍﻟﳣﺪﻳﺪﺍﺕ
ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ
.32A-N • ﻋﲆ ﻃﺮﻑ ﺍﻟﻔﺎﺯ )ﺍﻟﻄﺮﻑ ﺍﻟﺬﻱ ﺗﺼﻠﻪ ﻛﻬﺮﺑﺎﺀ ( ﺑﻮﺍﺳﻄﺔ ﻓﺎﺻﻞ ﻛﻬﺮﺑﺎﺀ ﺃﻭﺗﻮﻣﺎﺗﻴﲄ
23 ﺛﺎﻥٍ ﻋﻨﺪ ﺍﻟﻄﺮﻑ ﺍﶈﺎﻳﺪ ﺑﲔ ﺍﳉﻬﺎﺯ ﻭﺍﻟﳣﺪﻳﺪﺍﺕA-N • ﻟﻜﻨﻨﺎ ﻧﻮﺻﻴﲂ ﺑﻌﻤﻞ ﺗﻮﺻﻴﻠﺔ ﺑﻔﺎﺻﻞ ﻛﻬﺮﺑﺎﺀ ﺃﻭﺗﻮﻣﺎﺗﻴﲄ
.ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﰲ ﻫﺬﺍ ﺍﻟﻨﻮﻉ ﻣﻦ ﺍﻷﺟﻬﺰﺓ
.• ﳚﺐ ﺗﻮﻓﲑ ﺍﻟﻔﻮﺍﺻﻞ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﻦ ﺟﺎﻧﺐ ﺍﳌﺴﳤﻠﻚ
.• ﰲ ﺣﺎﻟﺔ ﺣﺪﻭﺙ ﺃﻱ ﻋﻄﻞ ﻻ ﺗﻔﺘﺤﻮﺍ ﻏﻄﺎﺀ ﺍﳉﻬﺎﺯ ﻭﻻ ﲢﺎﻭﻟﻮﺍ ﺇﺻﻼﺣﻪ
.• ﻳﺮﴁ ﺍﻻﺗﺼﺎﻝ ﺑﺄﻗﺮﺏ ﻣﺮﻛﺰ ﺧﺪﻣﺔ ﻣﻌﳣﺪ
68