To reset the total dosing time, select "Reset total" and
press the PTK.
Select "Reset log" and press the PTK to reset the daily
dosing times (7 days) from the "Dose log".
Select >> NEXT >> / PTK and again >> NEXT >> / PTK
to return to the main screen.
Daily dosing time CO
2
The "Dose log" allows you to see the daily dosing time
over a period of 7 days. The values are displayed per day
in hours and minutes. The "Dose log" is reset at the
beginning of each cycle (day).
Example
On the night of day 7 you see the log data of day 7
(2h01). If the lights go on after the night of day 7 and day
1 starts again, the old log data of day 1 (1h17, from a
week ago) is reset and the log function of day 1 starts
again.
Select "Dose log" in the main screen:
TMP = 21.8 °C
RH =
63 %
CO2 =
848 PPM
=> Dose log
Press the PTK to read the daily dosing times.
-1 01h17
-2 01h14
-3 01h28
-4 01h23
Scroll up and down by turning the PTK.
Press the PTK to return to the main screen.
8.7 CO
min/max
2
Select >> NEXT >> in the next screen:
Total CO2
1h08
Reset total
Reset log
=> >> NEXT >>
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
CO2 Min 504 ppm
CO2 Max 817 ppm
Reset min/max
=> >> NEXT >>
Min/max values are displayed.
These measurements will not be stored in case of a power
failure.
Select "Reset min/max" to reset. Select >> NEXT >> and
press the PTK to return to the main screen.
9. Sensor settings: 2,000 or 10,000
ppm
Reboot your controller.
After a few seconds you enter the next screen:
=> System settings
CO2 Setup
CO2 calibration
>> HOME <<
"Select "System settings" and press the PTK. You enter
the next screen:
System settings
=> CO2 Setup
CO2 calibration
>> HOME <<
Select "CO2 Setup" and press the PTK.
Select "CO2 sensor" in the next screen:
=> CO2 sensor
2000
Delay/dose
CO2 pulse
<< BACK <<
Here you can specify which sensor you want
use. By default, it is set to 2,000 ppm. By turning the PTK
you can activate the 10,000 ppm sensor. Your controller
is now suitable for measuring and controlling from 300
to 10,000 ppm, in increments of 50 ppm.
NOTE: If you want to enable the 10,000 ppm option,
you need to purchase a sensor that is suitable for
measuring up to 10,000 ppm. If you enable this
function with the wrong sensor, the controller will
20