Herunterladen Inhalt Inhalt Diese Seite drucken

Temperature Settings; Set Hysteresis; Set Temp Offset; Set Night Delay - TechGrow Clima Control Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Clima Control:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

After a few seconds you will automatically return to the
main screen.

10. Temperature settings

You are in the main screen. Press the PTK once and
select "TMP".
=> TMP = 33.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
Press the PTK.
=> Temp day
28.0°
Temp night 28.0°
Temp +/-
2.0°
>> NEXT >>
Select "Temp day", press the PTK and set the desired day
temperature by turning the PTK.
Press the PTK to confirm.
Temp day
28.0°
=> Temp night 28.0°
Temp +/-
2.0°
>> NEXT >>
Select "Temp night" and press the PTK. Turn the PTK to
set the desired night temperature.
Press the PTK to confirm.

10.1 Set hysteresis

You are in the main screen.
Press the PTK once and select "TMP".
=> TMP = 30.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
Press the PTK.
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
Temp day
28.0°
Temp night 28.0°
=> Temp +/-
2.0°
>> NEXT >>
Select "Temp +/-" and press the PTK. Turn the PTK to set
the desired hysteresis.
Press the PTK to confirm.

10.2 Set Temp offset

Although the temperature sensor is very accurate, it may
be desirable to align it with other measuring equipment.
"Temp offset" allows you to adjust the indication with
+ or - 5.0 °C.
Select "Temp offset" in the TMP menu and press the
PTK.
=> Temp offset 0.0°
Night delay
5m
TMP set 26 C
>> NEXT >>
TMP +/- 1.5 C
Turn the PTK to select the desired degree of correction.
Press the PTK to confirm.

10.3 Set night delay

This function allows you to adjust the bridging time
between the moment that the light goes out and the
night temperature is valid. During this period the fan will
not start to run faster.
Select "Night delay" in the TMP menu and press the PTK.
Temp offset 0.0°
=> Night delay
5m
TMP set 26 C
>> NEXT >>
TMP +/- 1.5 C
Turn the PTK to select the desired time delay (up to 60
minutes).
Press the PTK to confirm.

10.4 Minimum/maximum temperature values

Select >> NEXT >> on the second page of the TMP
menu and press the PTK.
19