Potential change-over switch
The potential change-over switch (C) is located between contact
rows (A) and (B) of the TERMSERIES adaptor. It is used to switch
D
the potential of the lower contact row (B) to the "+" or "-" potential of
the auxiliary voltage.
The auxiliary voltage potential is either fed in via the plug-in
connectors (D) (F10, F20, Sub-D) or via the separate push-in
connections (E).
A
When delivered, the potential change-over switch is in the
"-" position (positive-switching logic).
B
Installation
Depending on the wiring logic, the TERMSERIES adaptor is
plugged into the
of the input (A1/A2) (Figure 2) or the output (11/14) (Figure 3) of
the TERMSERIES. The adaptor must be heard and felt to snap into
place.
Then, the ribbon cable or Sub-D plug must be plugged in as well as
the auxiliary voltage connected to the separate push-in connections
if necessary.
In order to loop the auxiliary voltage, the push-in connectors
are duplicated (except TIA SUBD). The loop can conduct 10 A
Figure 2a
maximum.
The distance between the cable conduits must be at least 140 mm.
Figure 2b
We recommend 160 mm for easier installation.
Installation tip: First plug the adapters into the TERMSERIES
Figure 2a:
Figure 2b:
Figure 3a:
Figure 3a
Figure 3b:
Figure 3b
De-installation
• Power down the system!
• Remove cabling
• Use a screwdriver (e.g. SD 0.6x3.5x100, order number
9008330000) to lever out the adaptors via the guides provided
(Figure 4)
Block diagram
Figure 5a
Figure 5b
Figure 5c
1
2
Figure 5a
9
7
5
3
1
10
8
6
4
2
Figure 5b
Technical data
Auxiliary voltage:
Continuous current:
Wire cross-section:
11
10
9
4
3
2
1
Operating temperature:
Further details on the push-in auxiliary voltage connection can be
found under part number 1875050000 at http://catalog.weidmueller.
com.
Figure 5c
>>>> cross-connection channels <<<<
products before snapping the entire block onto the
mounting rail!
Installation for 24 V DC input (A1/A2), positive-
switching logic, potential change-over switch to "-".
Installation for 24 V UC input (A1/A2), negative-
switching logic, potential change-over switch to "+".
Installation for output (11/14), positive-switching
logic, potential change-over switch to "+".
Installation for output (11/14), negative-switching
logic, potential change-over switch to "-".
TIA F10, TIAL F10
TIAL F20
TIA SUBD
24 V DC ±20 %
max. 1 A (per conductor or as total
current)
< 1.5 mm²
(push-in auxiliary connection)
-40...+60 °C
Weidmüller t
Weidmüller Interface GmbH & Co. KG
Operating Instructions
en
Klingenbergstrasse 16
TERMSERIES Adaptor
32758 Detmold
Germany
www.weidmueller.com
TIA F10
1463520000
TIA SUBD
1463530000
TIAL F10
1463540000
TIAL F20
1463550000
R.T.No. 1477400000/02/08.14
IND. CONT. EQ
IVD3
Safety instructions
DANGER
For safe installation and safe operation of the device,
heed the following:
• The device must only be installed by qualified spe-
cialists who are familiar with national and internation-
al laws, provisions and standards in the relevant region
of application.
WARNING
• All applicable technical requirements and operating in-
structions must be taken into account before installa-
tion, commissioning and maintenance.
• Do not plug and unplug under load!
• The potential of the auxiliary voltage must correspond
to the potential of the I/O component assembly.
• Ensure the correct polarity of the potentials. Avoid in-
correct polarity!
• Heed the technical data!
• The adaptor is installed in the cross-connection chan-
nels of the TERMSERIES products and not on the con-
nection terminals.
NOTICE
• The TERMSERIES adaptor is suitable for positive and
negative switching logic in 24 V DC circuits.
• The potential switch must be set prior to installation.
cULus-approval
NOTICE
• Use copper conductors only.
• The device shall only be used in an environment with
pollution degree 2.