4.3.1

Intended use

Operation is only permitted with the following controllers:
CE
TST FUF2-A,-C,-F Series
TST FU3F-A,-C,-F Series
TST FUH2-C Series
TST FU3F-AU, -CU, -FU Series
TST FU3H-F Series
TST FU3H-FU Series
TST FUZ2-A, -B, -C Series
TST FUZ2-CX, -G, -L, -P, -S Series
4.3.2
Technical data for Europe
All inputs shall be connected potential-free or:
 < 4 V: inactive
logical 0
 >16 V: active
logical 1
 min. duration of input control commands: > 100 ms
Dimensions (LxWxH)
112 x 83 x 30 mm
Operation
-20 °C to +65 °C
Temperature
Storage
-20 °C to +70 °C
Weight
approx. 150 g
Equipment type
Input and output expansion board
Protection type
IP 00
Protection class
--
Supply voltage
24 VDC ± 20 %
Power consumption
(without relays and outputs)
max. 2 W
Current carrying capacity
max. 1.8 A
Connection/interface
X30a and X30b: System interface
(internal connection to door controller)
1x RS-485 as external interface
1x RS-485 as external interface parallel
to X30a e.g. for connection of a
diagnostic tool
Other
1 LED (see chapter LED display)
Inputs
X33 (IN 21), X34 (IN 23),
24 VDC / typ.15 mA,
X36 (IN 24 – IN 26)
max. 26 VDC / 20 mA
6 | 10
TST RFUxIO-E
TST_RFUxIO-E_INSTALL_MUL_rev2.docx
The 24 V outputs and transistor outputs are electronically fused
and may be loaded with max. 1.1 A (@23 °C) (resistive loads only)!
UL
Relays OUT 5 – OUT 8
Relays OUT 9 – OUT 10
Relay contact (general)
Digital Output
+24 V
Connection
X31
310-319
X32
320-325
X33
330-335
X34
340-342
X36a
360-363
Machinery Directive: 2006/42/EC
EMV: 2014/30/EU
Applied harmonized standards:
EN 60335-1:2012 / AC:2014
Section: Chapters 7, 10, 11,14,19, 22, 23, 24, 29
EN 60335-2-103:2015
Section: Chapters 7, 10, 11,14,19, 22, 23, 24, 29
EN 61000-6-1:2007
Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
EN 61000-6-2:2005 / AC:2005
Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
Applied national technical specifications:
EN 12453:2017 Section 5.3
Outputs
Normally open contact with common
COM port.
Max. 230 VAC / 3 A in total are
allowed.
Changeover contact free of potential.
The same switching voltage shall be
used for both relays!
max. 240 VAC/3 A, min. 10 mA
OUT 11: 1 x 24 V / min. 10 mA / max.
100 mA, normally open, +24 V
switching!
24 VDC Power supply output
Cable size
Tightening
Stranded with
torque
Solid
wire end
ferrule
0,2 - 2,5 mm²
0,25 - 1,5 mm²
0,35 - 0,4 Nm
0,2 - 2,5 mm²
0,25 -1,5 mm²
0,35 - 0,4 Nm
EC installation declaration
2019-03-05
FEIG ELECTRONIC GmbH
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
4.4
UL-Ratings
Supply
24 VDC
Class 2 output
Class 2 output, max. 1.8 A
Maximum surrounding air
65 °C
temperature
Pollution degree
For use in an environment with
pollution degree 2.
X30a
Supply input, 24 VDC / max. 1.8 A,
Class 2, (and internal RS485 bus)
X30b
RS-485 and power interface for
diagnostics, Class 2
X33
Input 21, 22; 24 VDC each /
max. 20 mA, Class2
2x digital output (OUT 11/2F), 24 VDC /
max. 200 mA, Class 2
X34
Input 23; 24 VDC each / max. 20 mA,
Class 2
X36/36a
1
Input 24, 25, 26; 24 VDC each / max.
20 mA, Class 2
3x digital output (OUT 2C/2D/2D/2E),
24 VDC each, 200 mA, Class 2
1
Note: The maximum load of all Class 2 outputs shall not exceed 0.7 A
in any combination.
Maximum load for each single output:
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
X31 Relays Outputs
2
C300, R150 (Pilot Duty)
(OUT 5,
OUT 6,
Maximum total load at all four outputs:
OUT 7,
OUT 8)
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
120 / 240 VAC, 180 VA (Pilot Duty)
125 / 250 VDC, 28 VA (Pilot Duty)
Maximum load for each single output:
2
X32 Relays Outputs
250 VAC, max. 3 A G.P.
(OUT 9,
30 VDC, 3 A G.P.
OUT 10)
C300, R150 (Pilot Duty)
2
The relay terminals X31 and X32 can be connected either to the mains
voltage, low voltage or class 2 circuits. Mixing different voltage circuits
within one terminal is not permitted.
The changeover contacts (OUT9/OUT10) on terminal X32 are also
intended for connection to the same voltage circuits. The connection of
different voltage circuits is not permitted For voltages above 150 V, it is
necessary that the "COMMON" terminals of OUT9 and OUT10 have the
same voltage potential.