Herunterladen Inhalt Inhalt Diese Seite drucken

Finder 7E.23.8.230 Montage- Und Bedienungsanleitung Seite 5

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembly and operating instructions Type 7E.23
32 A 2-Ways Single Phase active power energy meter with Serial Modbus interface, Fig. 1
Description
Energy meter with serial Modbus interface (RS-485)
enables the reading of all relevant data like consump-
tion, current, voltage, power (active and reactive). The
reactive power (idle power) can only be read on the
Modbus interface.
Technical data
■ Fig. 2
Connection
diagram
■ Fig. 3
Dimensions
■ B according to EN50470-3,
Accuracy class
1 according to IEC62053-21
■ I
Reference, Maxi-
ref
mum, initial current
■ 230 V
operating voltage
Tolerance −20%/+15%
■ 00 000,00...999 999,9 kWh
Counting range
■ Integrated Modbus interface
Output
(see page with the telegram
structure)
■ Conductor cross-section max. 6 mm
Connections
Main circuit
screwdriver pozi no. 1, slot no. 1,
torque 1,2 Nm
■ Conductor cross-section max. 2,5 mm
Connections
Control circuit
screwdriver pozi no. 0, slot no. 1,
torque 0,5 Nm
■ −25... +55°C (noncondensing
Operating
temperature
according standard EN50470)
■ Mechanical M2
Environment
Electromagnetic E2
Indicating elements (Fig. 4)
■ Indicates the total consumption
T
(kWh)
■ Indicates the total feeding back
T
(kWh)
■ Indicates the instantaneous power
P (kW)
Current
Current
■ Indicates the voltage
U (V)
■ Indicates the current
I (A)
■ Pulsates according to the amount
2000 pulses/kWh
of used power.
323007734-001
= 5 A, Im
= 32 A, Ist
20 mA
ax
=
, 50 Hz
AC
= consumption (pos.)
= feeding back (neg.)
Notes before connecting
In order to avoid moisture in the meter due to condensate
build-up, acclimatise the meter at room temperature for
about half an hour before connecting.
Attention!
These devices must only be installed by a professional
electrician, otherwise there is the risk of fire or the risk
of an electric shock.
Operation of the LCD display
See page with LCD menu navigation.
Installation instructions
The energy meter can be attached to a 35 mm rail
(EN60715TH35).
The meter can be used only in installation cabinets.
Declaration of Conformity CE
,
2
We, Finder Gmbh herewith declare, on our own respon-
sibility that the products:
,
2
■ 7E.23.8.230.0204
■ 7E.23.8.230.0214
which this certificate refer to, are in accordance with
the directive 2004/22/EG (MID) and the following
standards:
■ EN50470 parts 1 and 3 (electronic meter), of
October 2006.
ESD on equipment side: 13 kV.
The following energy meters are approved for energy
billing:
7E.23.8.230.0214
Trebur, 01.03.2015
Conformity Assessment Body:
METAS-Cert, Nr. 1259
CH-3003 Bern-Wabern
Signed: Manfred Cloot, Head of Technic
03.2015
English
Subject to change without notice

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis