INSTALLATION AND MAINTENANCE MANUAL
EN
F9 Manual function. Tests. Priming the
pumps.
Press the F key until you reach F9 MANUAL FUNCTION.
Press ENTER in order to enter this function.
The following options appear:
FUNCTION. MANUAL
de-activated
FUNCIÓN. MANUAL
only pH pump
Select the option desired using the arrows.
Press ENTER to validate.
8. MAINTENANCE
• Check regularly that values correspond between the
estimated reading of ClF from the panel with a direct
analysis of the water in the pool.
• Clean the probes of any incrustations or layers of dirt.
• Clean the entry filter, proceeding as is indicated in
Figure 14:
• Remove the nut from the earth point.
• Remove the plastic restraining bolt.
• Remove the filter with care so as to conserve the ring
seals.
• Clean the filter with plentiful amounts of water.
• EQUAL Complet equipment can check the reliability
and quality of the pH and Redox probes. If quality values
are lower than 30% the replacement of the probe is
recommended.
• pH and Redox probes are not included in the
manufacturer's guarantee.