Verschweißter kragenbolzen ausfräsung im hauptträger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Art.-No. K128
Routing length L in main beam with respect to secondary beam member
height H
N
Secondary beam
height H
N
[mm]
220
240
260
280
300
320
340
360
380
400
Pre-drill distance t
beam member height H
Secondary beam
height H
N
[mm]
220
240
260
280
300
320
340
360
380
400
Important information:
Please contact a licensed design professional
for the design of any connection not listed in
the tables. Full thread screws may be used to
reinforce potential splitting perpendicular to
grain or transverse shear failure.
Page 2/4
Length L without perpendicular to grain tension reinforcement
in main- and secondary beam with respect to secondary
1
N
Pre-drill distance t
Installation instructions
RICON® S 200/80 VS
Welded collar bolt
Routing in main beam
RICON® S 200x80
[mm]
210
220
230
240
250
-
-
-
-
-
RICON S 200x80
for secondary beam
1
Distance t
1
[mm]
50
60
70
80
90
-
-
-
-
-
header
full thread screw with
self tapping tip
ETA-10/0189
joist