INSTA ACO DRAIN instalight 1067 Bedienungsanleitung Seite 10

Bodenlichtlinie;

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
®
The ACO DRAIN
Lightline is used for outdoor underfloor lighting systems.
For this reason, the cover sections of the ACO DRAIN
EN 60589-1-2000 + A11-2000. This is certified by the symbol
Important note:
• The ACO DRAIN
®
Lightline is suitable for supporting walking loads and rolling loads from vehicles with
air-inflated tyres.
• The load applied on the elements must not exceed 5000 kg.
®
• The ACO DRAIN
Lightline can be used for walkways, parking lots and car access ways.
It is not approved for use on motorways.
Safety warning
Attention: To prevent injury, always replace broken or splintered cover sections.
The ACO DRAIN
®
Lightline lamps emit soft diffuse light and can therefore be used as orientation lights.
®
The ACO DRAIN
Lightline is based on LED technology. Depending on the type chosen, either static light or a
colour sequence can be realized.
This can be achieved by using different LED-Floorline lamps:
• monochromatic LED-Floorline lamps in white, blue and green
• RGB LED-Floorline lamps
The RGB LED-Floorline lamps are composed of 3 separate sections.
The Floorline lamps are provided for installation in the well-known ACO DRAIN
®
ACO DRAIN
drainage channels of the following types: Multiline V 100 S Type 10.0 (length 1 m ACO DRAIN
Art. No. 12450) and Multiline V 100 S Type 10.1 (length 0.5 m ACO DRAIN
edge. Close the drainage channel line at the ends with the closing plate (ACO DRAIN
Various power supply units are available for the supply of the LED-Floorline lamps.
The power supply units have the following features:
• maintenance-free due to electronic short-circuit protection
• no-load protection
• over-temperature protection
• safety extra-low voltage on the secondary side (SELV as per EN 60950), DC
Operation of the LEDTRIX
The use of sequencers is described in separate operating instructions.
Safety warnings
Attention: To avoid the risk of electric shocks, it is absolutely vital to observe the following
instructions.
• Pull out the mains plug before opening the supply unit.
• It is strictly forbidden to make modifications of the ready-made connecting lines and connectors
and of the internal wiring of the supply unit.
• Defective lines may only be replaced by original lines of the manufacturer.
• Defective Floorline lamp connecting lines may only be replaced by the manufacturer.
10
®
lines requires a so-called LEDTRIX
®
Lightline are suitable for heavy-duty applications as per
on the luminaire.
®
Art. No. 12452) with stainless steel
®
sequencer.
ACO DRAIN
®
drainage channels. Use only
®
Art. No. 12485).
®
Lightline
®