WATER FILTRATION SYSTEM
EN
PERFORMANCE DATA SHEET
BRAND: ZEPTER INTERNATIONAL - MODEL: PWC-670
This system has been tested and certified by the Water Quality Association according
to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI, 53, and 58.
Max.
Allowable
Substance
Concentration
(mg/L)
Arsenic (Pentavalent)
0.010
Barium
2.0
Radium 226/228
5 pCi/L
Cadmium
0.005
Chromium (Hexavalent)
0.1
Chromium (Trivalent)
0.100
Lead
0.010
Copper
1.3
Selenium
0.05
TDS
<187.5
Aesthetic Chlorine
≥ 50% reduction
VOC*
≥ 95% reduction
While testing was performed under laboratory conditions, actual performance may vary.

GENERAL OPERATING INFORMATION:

Rated Capacity
Min-Max operating pressure:
Min-Max feed water temperature:
Rated Service Flow
Daily Water Production Rate*
Product Efficiency Rating*
*Daily Water Production Rate and Product Efficiency Rating can be differentiated according to the inlet
water pressure and water temperature.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
Average
Average
Average
Minimum
Percent
Influent
Effluent
Percent
Reduction
(mg/L)
(mg/L)
Reduction (%)
(%)
0.0511
0.001
93.9
97.8
11.4
0.309
93.1
97.3
25 pCi/L
5 pCi/L
N/A
N/A
0.035
0.00056
95.8
98.4
0.324
0.00446
95.9
98.6
0.281
0.00174
98.4
99.4
0.201
0.00149
98.1
99.3
3.223
0.063
96.4
98.0
0.121
0.00192
96.9
98.4
751.8
57.8
91.4
92.3
2.07
0.56
54.53
72.8
0.3274
0.0008
94.3
99.7
681.4 L (180 gallons) - (for VOC)
16655.8 L (4 400 gallons) - (for Aesthetic Chlorine)
138kPa ~ 827kPa (20 psi ~ 120 psi)
5 ºC ~ 35 ºC (41ºF ~ 95 ºF)
0.26 L/min (0.07 GPM)
168.5 L/d (44.5 GPD)
20.7 %
• Refer to the owners manual for specific installation instructions, manufacturer's
limited warranty, user responsibility, and parts and service availability.
• The influent water to the system shall include the following characteristics:
- No organic solvents
- Chlorine: < 2 mg/L
- pH: 7 - 8
- Temperature: 5 ºC ~ 35 ºC (41 ºF ~ 95 ºF)
- Iron: < 2 mg/L
- Turbidity: < 1 NTU
- Hardness: < 1 000 mg/L
• For parts and service availability, please contact your local Zepter dealer.
• This system has been tested for the treatment of water containing pentavalent
arsenic (also know as As(V), As(+5), or arsenate) at concentrations of 0.050
mg/L or less. This system reduces pentavalent arsenic, but may not remove
other forms of arsenic. This system is to be used on water supplies containing
a detectable free chlorine residual at the system inlet or on water supplies
that have been demonstrated to contain only pentavalent arsenic. Treatment
with chloramines (combined chlorine) is not sufficient to ensure complete
conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic
Facts section of this Performance Data Sheet for further information.
• Efficiency rating means the percentage of the influent water to the system
that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
• The product water should be tested every 6 months to ensure that the
contaminants are being reduced effectively. Please contact your local Zepter
dealer. to initiate this service.
• This reverse osmosis system contains a replaceable treatment components,
critical for the effective reduction of total dissolved solids and that product
water shall be tested periodically to verify that the system is performing
properly. Replacement of reverse osmosis component should be with one of
identical specifications, as defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance.
• The estimated replacement time of filter, which is a consumable part, is not
an indication of quality guarantee period, but it means the ideal time of filter
replacement. Accordingly, the estimated time of filter replacement may be shortened in
case it is used in an area of poor water quality.