Herunterladen Inhalt Inhalt Diese Seite drucken
Frico EZ212 Bedienungsanleitung
Vorschau ausblenden Andere Handbücher für EZ212:

Werbung

SE
.... 14
DE
.... 24
GB
.... 16
ES
.... 27
Elztrip EZ200
NO
.... 18
NL
.... 29
FR
.... 20
FI
.... 32
RU
....22
PL
.... 34

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Frico EZ212

  • Seite 1 Elztrip EZ200 ..14 ..18 ..20 ..22 ..16 ..24 ..27 ..29 ..32 ..34...
  • Seite 2 Many of Frico's products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not.
  • Seite 3 El Reglamento no se aplica a instalaciones en vehículos, en alta mar o al aire libre. Muchos de los productos de Frico pueden utilizarse como aparatos de calefacción local (según se define en el Reglamento (UE) 2015/1188) y con fines de calefacción técnica. Corresponde al instalador responsable de la instalación evaluar si se aplica el Reglamento sobre diseño ecológico o no.
  • Seite 4: Installation

    Elztrip EZ200 ø20,5 (2x) [mm] [mm] [mm] [mm] EZ208 EZ212 EZ217 1221 EZ222 1520 1200 Installation Tak / Skinne Wire Roof / Plafond Fig.1...
  • Seite 5 Elztrip EZ200 Positioning a < H Dh = 1,5 - 2 m Fig. 2: Positioning vertically EZ200 [mm] 1800 Fig. 3: Minimum mounting distance...
  • Seite 6 Elztrip EZ200 Controls Type HxWxD [mm] 87x87x53 TAP16R 87x87x55 TEP44 155x87x43 82x88x25 RTX54 TAP16R TEP44 RTX54 SKG30 PDK65 115x85x40 SKG30 102x70x50 PDK65 Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188 Type HxWxD [mm] 165x57x60 KRT1900 165x57x60 KRTV19 KRT1900 KRTV19 SE: Regleringar för installationer som inte omfattas av Ecodesign, förordning (EU) 2015/1188...
  • Seite 7: Technical Specifications

    Amperage (3) Max. surface Weight (5) E-nr (SE) EL-nr (NO) temperature (4) [kg] EZ208 230V~ 85 747 56 543 26 01 EZ212 1200 230V~ 85 747 60 543 26 02 EZ217 1700 230V~ 85 747 64 543 26 03 EZ222...
  • Seite 8: Wiring Diagrams

    Elztrip EZ200 Wiring diagrams Internal wiring diagrams EZ2.. 230V~ EZ2.. 400V~ 230V TAP16R 230V TAP16R Control by thermostat 230V~ °C TAP16R °C TAP16R 230V 230V L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 EZ200 EZ200...
  • Seite 9 Elztrip EZ200 230V TAP16R / SKG30 Control by thermostat and black bulb sensor 230V~ 230V TAP16R / SKG30 °C TAP16R °C TAP16R 230V 230V SKG30 SKG30 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 EZ200 EZ200...
  • Seite 10 Elztrip EZ200 230V TAP16R / SKG30 Control by thermostat and presence detector 230V~ 230V TAP16R / SKG30 °C TAP16R °C TAP16R 230V 230V N N L PDK65 N N L PDK65 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1...
  • Seite 11 Elztrip EZ200 400V2 TAP16R Control by thermostat and relaybox 400V2~ 400V2 TAP16R °C TAP16R °C TAP16R 230V 230V L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 EZ200 EZ200 EZ200 L3 L2 L1 L3 L2 L1 L3 L2 L1 EZ200...
  • Seite 12 Elztrip EZ200 Control by thermostat, relaybox and presence detector 400V2~ 400V2 TAP16R / SKG30 °C TAP16R 230V N N L PDK65 L3 L2 L1 L3 L2 L1 L3 L2 L1 EZ200 EZ200 EZ200 L3 L2 L1 L3 L2 L1 L3 L2 L1 L3 L2 L1 L1 L3 L1 L3 L2...
  • Seite 13 Elztrip EZ200 Control with thermostat and contactor 230V~ - for installations not covered by the Ecodesign Regulation (EU) 2015/1188 230V~ Thermostat EZ2.. EZ2.. EZ2.. Control with thermostat and contactor 400V2~ - for installations not covered by the Ecodesign Regulation (EU) 2015/1188 230V~ Thermostat 400V~...
  • Seite 14: Montage

    Elztrip EZ200 Montage- und Betriebsanleitung Allgemeine Anweisungen minimalen Montageabstand siehe Abb. 3. Bitte lesen Sie diese Anweisungen vor der Standardbeschläge (2 St.) für die Montage Montage und Verwendung gründlich durch. sind im Lieferumfang enthalten, sie befinden Bewahren Sie diese Anleitung zum späteren sich im Anschlusskasten.
  • Seite 15 Elztrip EZ200 • TAP16R, elektronisches Thermostat, Leistung wird dadurch nicht beeinträchtigt. inklusive: Bei allen elektrischen Heizgeräten können durch das Zusammenziehen - Elektronischer Raumtemperaturkontrolle und Dehnen des Materials aufgrund und Wochentagsregelung der Temperaturänderungen kurze - Raumtemperaturkontrolle mit Erkennung Knackgeräusche auftreten. offener Fenster •...
  • Seite 16 Elztrip EZ200 Sicherheit • Für sämtliche Installationen von elektrisch beheizten Geräten muss zum Brandschutz ein FI-Schalter mit 300 mA vorgesehen werden. • Während des Betriebs oder beim Abkühlen können die Oberflächen des Gerätes heiß sein! • Das Gerät darf nicht vollständig oder teilweise mit Textilien oder ähnlichen Materialien abgedeckt werden, da sonst Brandgefahr durch Überhitzung entsteht!