Thermostat THS406 (and hysteresis HYS406) limits the maximum flow temperature.
The pump is ON and it is OFF aftter reaching thermostat THS405.
Contemporarily there is the complete Valve closing.
5.6.5
De-Ice
The system has 2 different De-Ice functions.
ENA000 = 1: the Wood Boiler/Solar Pump is activated in Pause/Work modality when the temperature read by
the probe S1 goes under thermostat THS102.
ENA011 = 1: the heating circuit Pump is activated (mixer valve circuit) in Pause/Work modality when the
temperature read by the external probe S5 goes under thermostat THS503.
The parameter TIM000 is the Work time; TIM001 is the Pause time.
Thermostat on S1 for the Wood Boiler/Solar Pump De-Ice function
Thermostat Hysteresis THS102
Thermostat on S1 for the De-Ice Mixer circuit Pump
Thermostat Hysteresis THS103
Thermostat on S5 for the De-Ice Mixer circuit Pump
Thermostat Hysteresis THS503
Pumps' Work time (seconds) during De-Ice
Pumps' Pause time (minutes) during De-Ice
Wood Boiler/Solar Pump De-Ice enable
Mixer circuit Pump De-Ice enable
5.6.6
Summer - Winter
Thermostat on S1 for the automatic calculation of the Summer / Winter function
Thermostat on S5 for the automatic calculation of the Summer / Winter function
Waiting Time (minutes) for the 'SUMMER' validation for S5>THS500 or S1>THS101
Waiting Time (minutes) for the 'WINTER' validation for S5<THS500 or S1<THS101
Enable of the automatic Summer / Winter function (in the plants with external probe)
Forces the Summer state
5.6.7
Room Thermostat
Probe/Thermostat S5: Heating Circuit with Mixer Valve
ENA010=ON: connect to connectors 22-23 an open/close Ambient Thermostat contact. When the contact is
open the heating Pump is OFF. If the Ambient Thermostat is not used, short-circuit the connectors 22-23.
ENA010=OFF: connect to connectors 22-23 an Ambient Probe PT1000: the Pump functioning is in according
to the value of the thermostat THS502.
Probe/Thermostat S2: Heating Circuit direct
ENA020=ON: connect to connectors 16-17 an open/close Ambient Thermostat contact. When the contact is
open the heating Pump is OFF. If the Ambient Thermostat is not used, short-circuit the connectors 16-17.
ENA020=OFF: connect to connectors 16-17 an Ambient Probe PT1000: the Pump functioning is in according
to the value of the thermostat THS206.
Ambient Thermostat on S5
Hysteresis of thermostat THS502
ON:
Probe S5=Ambient Thermostat open/closed
OFF: Probe S5=Ambient Probe PT1000
Ambient Thermostat on S2
Hysteresis of thermostat THS206
ON:
Probe S2=Ambient Thermostat open/closed
OFF: Probe S2=Ambient Probe PT1000
5.6.8
Unblock Pumps
Unblock Waiting Time (days)
Working time in Unblock function (minutes)
Enable for P1 Out Unblock Control
Enable for P2 Out Unblock Control
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
Seite 22 / 32
KLIMA500 Anleitung
V3.0
Code
THS102
HYS102
THS103
HYS103
THS503
HYS503
TIM000
TIM001
ENA000
ENA011
Code
THS101
THS500
TIM007
TIM010
ENA009
ENA016
Code
THS502
HYS502
ENA010
THS206
HYS206
ENA020
Code
TIM005
TIM006
P1
P2