Herunterladen Inhalt Inhalt Diese Seite drucken

Bestron DFT45SW Gebrauchsanweisung Seite 19

Standventilator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
user's instructions
MontAGe - preparations for assembling
1. Unscrew the spinner from the motor-housing shaft (by turning it clockwise) and remove the spinner.
2. Unscrew the locking ring from the motor-housing (by turning it anticlockwise) and remove the ring from
the motor housing.
MontAGe - Assembling the fan
1. Fit the rear of the fan housing (B) onto the
motor-housing, making sure that the openings
are aligned precisely with the lugs on the motor
housing and that the grip is at the top.
2. Slide the locking ring onto the shaft, and screw it
tight (clockwise).
3. Slide the fan blades onto the shaft, making sure
that the notches are aligned precisely with the
two keys on the shaft.
4. Fit the spinner onto the shaft and tighten it
(anticlockwise) whilst preventing the fan blades
from moving.
5. The rim has five clamps (A). Carefully fit the rim
around the rear half of the fan housing, making
sure that the housing falls into the upper clamp
of the rim, so that you can connect the two halfs of the fan housing with the nut and bolt (C). Use a
crosshead screwdriver to screw the bolt into the nut.
6. Close the other clamps.
7. Loosen the stand lock fitted to the rear of the control unit.
8. Fit the fan onto to the upright, and tighten the lock.
operAtion - Ventilate
1. Set the fan on the floor, on a level surface.
2. Adjust the stand to the required height, see
Figure 4. Loosen the height lock (by turning it
anticlockwise). Adjust the stand to the required
height and tighten the height lock (by turning it
clockwise).
3. Tilt the fan to the required angle (see Figure 5).
You can set the fan:
a. to blow horizontally (position a) or angled
slightly downwards (position b). Tilt the
ventilator housing and motor housing to the
required angle.
b. to oscillate from left to right (with a sweep of
90 °). This will ventilate much of the room.
Press the oscillation button on the motor
housing fully in.
c. remain in the same position whilst the fan is
turning. This will ventilate one area. Pull out the oscillation button until
you hear it click.
4. Put the plug into the wall socket.
5. Switch on the fan by pressing one of the three speed buttons.
a. Speed 1 the fan operates at low speed.
b. Speed 2 the fan operates at normal speed.
c. Speed 3 the fan operates at high speed.
6. Stop the fan by pressing the stop button (position '0').