Herunterladen Inhalt Inhalt Diese Seite drucken

Required Tools And Materials - Facom BSYS.TK Original Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
EN

Required Tools and Materials

Before you begin, gather the required tools and
components listed below and ensure all are
accounted for .
Unpack the ToughSystem
System kit and make sure you have all the
necessary parts . The parts are located in the
shipping box . If any of the listed components in
your package are missing, please call Customer
Service before attempting to assemble .
Required tools and materials:
Note: Not included with the product .
• Rubber Mallet or Hammer
• Drill with set of drill bits (size according to
fasteners being used)
• Hex key of 5 mm
• Tape Measure
• Stud Finder (if installing on wood wall or
drywall)
• Pencil or Pen
• Carpenter's level (1.2 m (4-foot) long)
• Sturdy Ladder
• Safety Goggles
• Gloves
• Protective shoes
• Fasteners/washers for securing the rack unit to
the wall and anchoring it to the floor .
NOTE: Different walls are made of different
material; therefore, the package does not
include connecting fasteners . For the walls: use
a minimum of two 5–6 mm ( #10–1/4") screws
together with 16 mm (5/8") minimum outer
diameter washers, for each horizontal bar . Each
anchored screw shall withstand a minimum pull
force of 100 Kg (220 lbs.).
WARNING: Always choose screws and fittings
suitable for the mounting wall/floor, and with
sufficient load capacity . If you are unsure, it is
advisable to consult a professional
• Wood shelf: 25 cm (10") deep, 65 cm (26") long
or twice as long for using on adjacent units .
• Fasteners/washers for connecting an optional
shelf .
• Framing lumber of 2-by-4 framing lumber, 52"
long (per unit).
• If framing lumber is used - two spacers of 2-by-
4 framing lumber, 3" long (per unit),
• Shims for leveling the floor before anchoring
the unit to the floor .
22
NU-BSYS.TK_0317.indd 22
Workshop Racking
®
Pre-Assembly & Installation Considerations
WARNING: The FACOM ToughSystem
Workshop Racking System should be
assembled only after reading and fully
understanding this manual . Improper assembly
may cause safety hazards .
• Preparation is essential before beginning the
installation . All applicable instructions should
be reviewed and followed .
• The Workshop Racking System unit should
be assembled carefully and according to the
assembly instructions .
• To avoid trip and fall hazards the assembly area
should be cleaned and clear of all materials and
debris before installation .
• The Workshop Racking System unit should
be anchored to any floor such as concrete,
wooden, brick etc . Every column footplate
of each storage rail unit should be properly
anchored to the floor with screw sizes 5–6 mm
(#10–1/4") and 35–50 mm (1-3/8"–2") long.
• Fasteners used to secure the rack must be the
appropriate type for the wall and floor material .
(Fasteners are not included in the kit).
• The Workshop Racking System unit should be
installed on a clean and level surface . Since
few floors are perfectly flat, shimming may be
required for rack installation .
• Nut and Bolt connections should be tightened
according to the fastener manufacture's
recommended torque .
CAUTION:
• Do not install the Workshop Racking System
unit outdoors . Standard paint for indoor
products may not be sufficient for an outdoor
environment .
• Do not expose your Workshop Racking System
unit to corrosive or harsh material or abnormal
humidity . This may cause deterioration of the
surface paint and result in premature corrosion .
• Do not cut, weld, modify or attach anything
to the storage rack components . Any
modification may reduce the load capacity of
the components and damage the integrity of the
rack structure, therefore causing a safety hazard .
Any modification to any storage rack component
will void any warranties and guarantees .
• Do not install rack kit components with
products designed for another system .
Use the rack kit only with your ToughSystem
compatible modules . Using the rack kit with
another system may result in damage to the
system and personal injury to you and to others .
®
®
06/04/2017 14:17:50

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis