230V AC Base Models:
iCON eco15 – 72683501
iCON15 – 72591501
iCON30 – 72591601
iCON60 – 72591701
Surface Mounting iCON Fans on Wall
When surface mounting the iCON30 and iCON60 the supplied mounting skirt
should be used.
The iCON30 requires a 110mm diameter hole through the wall lined with a
100 mm id duct.
The iCON60 requires a 160mm diameter hole through the wall, lined with a
150 mm id duct
Surface Mounting iCON Fans on Ceiling
POSSIBLE CABLE
DUCT
ROUTING
JOIST
CEILING
MOUNTING
PLYWOOD
SKIRT
The iCON30 requires a 110mm diameter hole through the ceiling. The
surface mounted skirt to be fixed, with the screws provided, through the
plaster board into the support. The fan is then fitted into the skirt.
The iCON60 requires a 170mm diameter hole through the ceiling. The
surface mounted skirt to be fixed, with the screws provided, through the
plaster board into the support. The fan is then fitted into the skirt.
Page 5 of 8
9041548
Issue 3
06/10
Page 2 of 8
Recessing iCON Fans in Ceiling
POSSIBLE CABLE
ROUTING
CEILING
When recessing fans in the ceiling, a plywood support (min 18mm thick)
should be mounted between the ceiling joists. Fans should not be fitted to
unsupported plaster board.
The iCON 15 and iCON eco15 requires a 110mm diameter hole through the
ceiling. The fan to be fixed, with the screws provided, through the plaster
board into the support.
The iCON30 requires a 160mm diameter hole through the ceiling. The fan to
be fixed, with the screws provided, through the plaster board into the support.
The iCON60 requires a 190mm diameter hole through the ceiling. The fan to
be fixed, with the screws provided, through the plaster board into the support.
Electrical Installation
All electrical installation to be carried out by an approved electrician in
accordance with Part "P" U.K. Building Regulations and to the latest IEEE
standards, or the appropriate regulations in the country of installation.
The iCON requires a 230V 50Hz supply, it is double insulated so therefore
does not require an earth.
For fans mounted in Zones 1 & 2 as defined in section 701 BS7161:2008
Additional protection must be provided by a Residual current device (RCD)
with a rated residual operating current not exceeding 30mA .
Page 6 of 8
Air flow iCON Domestic Fan – 230V
Installation, Maintenance and Use
Airflow iCON fans are available in three model sizes and can be fitted to a
wall or ceiling. Each fan requires a suitable size hole through the wall or
ceiling which connects into a duct venting to the outside. The external
opening should be covered by a suitable external grill, available separately
from Airflow Developments Ltd.
Airflow iCON / iCON eco Model Options
Model iCON eco15
100mm Axial Fan with maximum capacity of 18.6
l/sec.
Model iCON15
100mm Axial Fan with maximum capacity of 21 l/sec.
Model iCON30
100mm Mixed Flow Fan with maximum capacity of 32
l/sec
Model iCON60
150mm Mixed Flow Fan with maximum capacity of 72
l/sec
The iCON range can be used as a simple extract fan operated by a remote
switch, or can be fitted with an internal control module, supplied to give a
range of control options including timer, humidity, motion sensor, pull cord,
trickle speed or combinations of these functions. Optional modules are
available separately and can be fitted at the time of installation or retrofitted.
The Airflow iCON fan has an IP X4 rating housing and is suitable for mounting
in Zone 1 or 2 in bathrooms, toilets, kitchens, utility rooms and inside shower
cubicles as defined in Section 701 BS7161:2008 (IEEE Wiring Regulations,
Seventeenth Edition ). The iCON also complies with the Building
Regulations, Approved Document F.
Do not place the ventilator near direct heat sources, e.g. radiant heaters, or
where temperatures can exceed 40°C (104°F).
Requires a 230V 50Hz single phase supply. Class II equipment. BS EN
60417. An external 3A fuse is required for each fan unit.
Note: Switches for fans shall be selected and sited in accordance with
BS7161:2008
All electrical installation to be carried out by an approved electrician in
accordance with Part "P" U.K. Building Regulations and to the latest IEEE
standards, or the appropriate regulations in the country of installation.
Page 3 of 8
iCON Fan wiring with no control module fitted
DUCT
N
L
3 AMP
SWITCHED FUSE
JOIST
Optional Modules for iCON and iCON eco 230V
iCON Fan wiring for control modules with external switching
PLYWOOD
A
N
N
L
L
3 AMP
LS
SWITCHED FUSE
iCON Fan wiring for control modules with no external switching
B
N
L
3 AMP
SWITCHED FUSE
Refer to instructions supplied with (optional) modules for further
information.
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER
SUPPLY BEFORE REMOVING THE COVER.
Warranty only covers the fan, not the reinstallation of this if required.
Page 7 of 8
Mechanical Installation
The iCON fan range can be recessed in
a wall or ceiling. A mounting skirt is
provided for surface mounting the iCON
30 and iCON 60.
CONDENSATION
To avoid the backflow of condensation
TRAP
into the fan in ceiling installation it is
good practice to fit a CONDENSATION
TRAP to the outlet duct of the fan.
Ensure free running of the fan impeller
and that flexible duct connections are
not over tightened to the fan outlet
spigot.
To avoid reduced flow, an elbow plenum should be used for all installations
which contain bending of ducting.
Front Cover Removal
The front cover of the iCON fan has a
bayonet type fitting. To remove, undo
the retaining screw at the bottom
edge of the cover using a
screwdriver, then rotate the cover a
UNDO THE RETAINING
few degrees anticlockwise and
SCREW AT THE
remove. To refit, reverse the above
BOTTOM EDGE OF
procedure.
COVER USING A
SCREWDRIVER.
Recessing iCON Fans in Wall
The iCON 15 and iCON eco15 requires a 110mm diameter hole through the
wall lined with a 100mm id (internal diameter) duct.
The iCON30 requires a 110mm diameter hole through the wall, counter bored
160mm to a depth of 75mm. The 110mm hole should be lined with a 100mm
id duct.
The iCON60 requires a 160mm diameter hole through the wall, counter bored
190mm to a depth of 75mm. The hole should be lined with 150mm id duct.
Page 4 of 8
When installed according to these instructions the iCON range of fans are completely safe.
The materials used do not constitute a hazard. The module covers are made of a flame
retardant material.
Cleaning
• The external housing of the fan can be wiped with a damp cloth. Do not
use household cleaners containing abrasives.
• Cleaning of the internal parts such as the impeller should be carried out
using a soft brush.
Note: Always ensure that the fan unit is isolated from the power supply
before inserting the brush into the impeller duct.
• Never clean any parts of the fan assembly by immersing in water or using a
dishwasher.
Warranty
Applicable to units installed and used in the United Kingdom. Airflow guarantees the
iCON, iCON eco fan units and iCON modules for 3 YEARS from date of purchase against
faulty material or workmanship. Warranty only covers the fan, not the reinstallation of this if
required.
In the event of any defective parts being found, Airflow Developments Ltd reserve the right
to repair or at our discretion replace without charge provided that the unit:
1. Has been installed and used in accordance with the fitting and wiring instructions
supplied with each unit.
2. Has not been connected to an unsuitable electrical supply.
3. Has not been subjected to misuse, neglect or damage.
4. Has not been modified or repaired by any person not authorised by Airflow
Developments Ltd
5. Has been installed in accordance with latest Building Regulations and IEEE wiring
regulations.
Airflow Developments shall not be liable for any loss, injury or other consequential
damage, in the event of a failure of the equipment or arising from, or in connection with,
the equipment excepting only that nothing in this condition shall be construed as to
exclude or restrict liability for negligence.
This warranty does not in any way affect any statutory or other consumer rights.
Manufacturer
Czech Republic
Germany
AIRFLOW DEVELOPMENTS Ltd
AIRFLOW LUFTTECHNIK GmbH
AIRFLOW LUFTTECHNIK GmbH
Aidelle House, Lancaster Road
o.s. Praha
Postfach 1208
Cressex Business Park
Hostýnská 520
D-53349 Rheinbach
High Wycombe
108 00 Praha 10
Germany
Buckinghamshire
Malešice
HP12 3QP
Czech Republic
Tel:
+49 (0) 222 69205 0
United Kingdom
Fax:
+49 (0) 222 69205 11
Tel:
+42 (0) 2 7477 2230
Email: info@airflow.de
Tel:
+44 (0) 1494 525252
Fax:
+42 (0) 2 7477 2370
Web:
airflow.de
Fax:
+44 (0) 1494 461073
Email: info@airflow.cz
Email: info@airflow.com
Web:
airflow.cz
Web:
airflow.com
AIRFLOW DEVELOPMENTS Limited reserve the right in the interest of continuous development to alter any or all specifications without prior notice.
Page 8 of 8

Werbung

loading

Inhaltszusammenfassung für Airflow iCON series

  • Seite 1 Web: airflow.cz Web: airflow.com AIRFLOW DEVELOPMENTS Limited reserve the right in the interest of continuous development to alter any or all specifications without prior notice. Page 5 of 8 Page 6 of 8 Page 7 of 8 Page 8 of 8...
  • Seite 2 Verwenden Sie keine Haushaltsreiniger, die Web: airflow.com Scheuermittel enthalten. AIRFLOW DEVELOPMENTS Limited behält sich das Recht vor, in der Interesse der andauernden Entwicklungen einen Teil oder alle Spezifikationen ohne vorherige Benachrichtigung zu verändern. Seite 5 von 8 Seite 6 von 8...

Diese Anleitung auch für:

Icon eco seriesIcon eco15Icon15Icon30Icon60