TF 50 HWI
E87 264 01
For maximum safety, please read the safety instructions that are included with each machine. Before using the machine,
please read the instructions.
Note the following information
Serial no:_______________ Date of purchase:________________
The machine is intended for drying and heating buildings where there is a need for temporary heating, drying or air
circulation. The machine shall be connected to an electrical supply protected by a residual current disconnect.
No more than 4 machines on one residual current disconnect (RCD). The machine can be used as a cooler, consult
El-Björn for replacement off water battery.

Machine data

Machine dimensions
H incl. air distributor
H excl. air distributor
W
D
Weight
Noise level
Motor and air side
Rated voltage
Power
Rated current
Electrical connection
Air flow with distributor
Fuse

Product description

The TF 50 HWI machine is built on a aluminium framework
equipped with insulating material on the inside to reduce the
noise level. The heater battery is protected inside the machine
and is connected via 25 mm Camlock couplings. The heat
to the machine is taken from hot water. The TF50 HWI's air
intake is on the rear.
The air is drawn through the filter and heater battery by the fan
and is then fed up to the air distributor and finally out into the
room through the air distributor vents.
In order to achieve the best drying and heating performance,
the machine should be positioned as centrally in the room as
possible.
It is very important that the fan runs continuously in order to
provide the best drying and heating performance.
1 Filter door
2 Filter
3 Heater battery complete
4 Potentiometer, factory setting 8
5 On/Off switch
6 Thermostat
7 Air distributor
8 Input water
2,200 mm
1,310 mm
760 mm
940 mm
148 kg
70 dB(A)
400 V
1.6 kW
2.5 A
3N~400V
3,900 m³/h
16A
9 Return water
10 Motor protection indicator
11 Frost protection indicator
12 Lifting eye
13 Fan motor
14 CEE 16A Input
15 Drain valve
16 Handle
17 Room sensor
Water side
Connector Camlock
Max water temp. in
Max input water pressure
Encapsulation class
Thermal power 50 kW at following values:
EC/EAA declaration of conformity, see
www.elbjorn.com
7.
17.
8.
9.
6.
3.
2.
1.
15.
25 mm
80°
16 bar
IP 44
- Water temp. 80–50°C
- Water flow 0.4 l/s
- Incl. air temp +5°C
GB