Power Linking
You can link up to 3 Maverick Storm 1 Wash products at 120 V, 6 products at 208 V, or 7 products at 230 V. Never exceed
this number. Power linking cords can be purchased separately.
Replacing the Fuse
1.
Disconnect this product from power.
2.
Using a Phillips-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.

Signal Connections

You can link the Maverick Storm 1 Wash to a controller or controller software using a DMX connection, an Ethernet
connection, or both. If using other Art-Net™, sACN, or Kling-Net -compatible products with the Maverick Storm 1 Wash,
you can control each individually on a single network. See the User Manual for information about how to connect and
configure the product for these signals.

Control Personalities

The Maverick Storm 1 Wash
Single Control
Basic (20-channel)
Standard (96-channel)
Advanced (178-channel)
Tour (216-channel)
Uses DMX, Art-Net™,
sACN, or WDMX
In Dual Control mode, the Movement protocol and the Pixels protocol cannot be the same.
DMX Connection
The Maverick Storm 1 Wash will work with a DMX controller using a 5-pin or wireless DMX data connection. A DMX
Primer is available from www.chauvetprofessional.com.
Art-Net™ Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
Kling-Net Connection
Kling-Net is a network protocol that allows auto configuration of display devices using a Neutrik® etherCON® RJ45
Ethernet connection. Refer to the ArKaos software manual for detailed instructions on programming this product.
For smooth-running operation, ArKaos Kling-Net requires a gigabit (1000 Mbps) Ethernet card
and network router.
ArKaos Kling-Net will only run Standard Pixels or Basic Pixels mode.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along an existing DMX or WDMX connection. The Maverick Storm 1 Wash supports RDM protocol that allows feedback
to monitor temperature and changes to menu options. Download the User Manual from
more details.
Maverick Storm 1 Wash QRG Rev. 2
QUICK REFERENCE GUIDE
uses
DMX, Art-Net™, sACN, WDMX, and Kling-Net for its control personalities:
Dual Control Movement
Basic (8-channel)
Standard (20-channel)
Advanced (26-channel)
Uses DMX, Art-Net™, or
sACN
Dual Control Pixels
Basic (57-channel)
Standard (76-channel)
Advanced (152-channel)
Uses DMX, Art-Net™,
sACN, or Kling-Net