Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6

SAFETY WARNING

▪ The minimum distance between the hob surface on which the pans stand
and the lower part of the hood must be 65 cm, unless otherwise specifi ed
in the installation instructions. If the hob installation instructions specify a
greater distance, it must be taken into account.
▪ The air collected must not be conveyed into a duct used to blow off
smokes from appliances fed with an energy other than electricity (central
heating systems, thermosiphons, water-heaters, etc.).
▪ Comply with the offi cial instructions provided by the competent autho-
rities in merit when installing the disposal duct. In addition, exhaust air
should not be discharged into a wall cavity, unless the cavity is designed
for that purpose.
▪ The room must be well aerated in case a hood and some other heat
equipment fed with an energy other than electricity (gas, oil, coal heaters,
etc) operate at the same time.
▪ In fact the intake hood, disposing of air, could create a vacuum in the
room. The vacuum should not exceed 0,04mbar. This prevents the gas
exhausted by the heat source from being intaken again. It is therefore
advisable to ensure the room contains air taps able to ensure a steady
fl ow of fresh air.
▪ Check the data label inside the appliance; if the symbol ( ) is printed,
read the following: this appliance has such technical particulars that it
belongs to class II insulation, therefore it must not be earthed.
▪ Check the data label inside the appliance; if the symbol ( ) is NOT prin-
ted, read the following:
When making the electrical connections, check that the current socket
has a ground connection.
▪ When making the electrical connections, check that the voltage values
correspond to those indicated on the data plate inside the appliance
itself. In case your appliance is not fi tted with a supply cord and a plug or
with other means for disconnection from the supply mains having a con-
tact separation in all poles that provide full disconnection under overvol-
tage category III conditions, that means for disconnection must be incor-
porated in the fi xed wiring in accordance with the wiring rules. If your unit
features a power lead and plug, position this so the plug is accessible.
▪ Always switch off the electricity supply before carrying out any cleaning