Safety advices:
 Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
 Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
 Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
 Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
 The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or electro-
cution.
 Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
 Choose a location of installation or mounting which complies to the
protection class IP 54.
 Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating. Abso-
lutely avoid that cables come near any source of heat (e.g. radioators,
other electrical devices, chimney, etc.).
State of the art 2016-12-15
Technical changes, design modifications, errors and misprints are subject to
change without prior notice.
Technical data:
KDG classification (nur BVS 20-69)
Downstream frequency range
Downstream gain
Attenuation: continuously adjustable
Equalization: continuously adjustable
Attenuation interstage: pluggable with jumpers
Equalization interstage: pluggable with jumpers
Downstream return loss
Downstream noise figure typ.
Max. downstream output level CSO/CTB
2
Upstream frequency range
Upstream gain
Attenuation: continuously adjustable (actuator)
Upstream sttenuation interstage: pluggable with jumpers
Upstream equalization interstage: pluggable with jumpers
Upstream noise figure
Test port at in-/output
RF Connectors
Power supply
Power supply
Power consumption
Power indicator
Ambient temperature range (acc. to EN 60065)
Ground connection
Maße (B × H × T) ca. | Dimensions (W × H × D) appr.
Protection class
1
According to KDG 1 TS140
2
CENELEC Raster 41 ch. 60 dB IMA
3
VHF I in forward path is not possible
4
Output, uni-directional, bi-directional
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
WEEE Nr.
DE14023300
Manufacturer
EWR contact adress
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
C (4.3)
1
85...1006 MHz
38 dB
0...15 dB
BVS 20-66 | 20-69
0...15 dB
0/2/4/6 dB
0/2/4/6 dB
premium-line
≥18 dB (-1,5 dB/oct.)
≤ 5,5 dB
107 dBµV
CATV Amplifiers
5...65 MHz
3
30 dB
Operation Instructions
0...15 dB
0 | 6 dB
0/3/6/9 dB
≤ 7 dB
-20 ±2,5 dB | -20 ±1,0 dB
4
F-Buchse | F-female
100...240 V~/50...60 Hz
30...65 V~/50...60 Hz
10 W
LED
-20...+50°C
Ground terminal
195 × 90 × 55 mm
IP 54