Attachment

Before attaching the product, make sure that the installation area can hold a minimum point load of 5 times
the product's weight.
The product must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the product is installed absolutely planar by using a water-level.
The product must be installed out of the reach of people.
The product must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: The holes for the installation are on the product.
Step 2: Hold the product onto the location where it is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the product in the desired position and tighten it.

Connection with the mains

The occupation of the control cables is:
Die Belegung der Steuerleitungen ist wie folgt:
Leitung
Pin
Braun
Einfahren
Schwarz
Ausfahren
Blau
Neutralleiter
Gelb/Grün
Schutzleiter
Der Schutzleiter muss angeschlossen werden!
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Before taking into operation, remove the transport securing!
If the canvas is in the top position or in the lowest position, it will stop automatically.
Steplessly adjustable height of the automatic endstop. The upper and lower stop position can be ajusted with
a screwdriver.
Caution: Never move the canvas manually!
The occupation of the control cables is:
International
Cable
"L1"
Brown
"L2"
Black
"N"
Blue
Yellow/Green
13/14
Pin
Raise
Lower
Neutral
Earth
This device must be earthed!
00037032.DOC, Version 1.3
International
"L1"
"L2"
"N"