MOUNTING MANUAL
dahlem
WALL LIGHT AND CEILING LUMINAIRE
TECHNICAL DATA
Manufacturer:
mawa design
Article No:
Voltage:
230 V / 50 Hz
Protection class:
Degree of protection:
Connected load:
90°
Driver:
Tridonic LCBI 15 W 350 mA
Basic phase cut Lp
EEI:
A++ bis A
IMPORTANT: Mounting only by an authorized elec-
trician! Never connect or disconnect the secondary
connection under voltage!
1a
1b
4x
90°
2
2x
We are pleased that you have decided in a favour of mawa design light.
WIRING DIAGRAM
da 1
L
con-
I
verter
IP 44
15 W
90°
N
1.*
1. DALI: DALI1 / DALI2
Light source of luminaire is allowed to be replaced
by manufacturer, a service technician commis-
sioned by manufacturer or a person with equivalent
qualifications only.
3
90°
WIRING
PRIMARY CONNECTION
230V/50Hz
L
N
Loss of guarantee!
Danger of PCB damage!
+
-
700 mA
Degree of protection of enclosure (IP44) for this
light can be provided only if included fitting aids
and gaskets are used.
4
4x
5
4x
6
Click!
mawa design GmbH | version of 10/11/2017 | errors and technical changes excepted | www.mawa-design.de
WIRING
PRIMARY CONNECTION
DC
DC
-
+
+
-
+
-
+
-
700 mA
700 mA
!
ATTENTION: Wall fixtures have to be chosen
according to local conditions! Please mount the
two catch-ropes and twist it into position, to avoid
interferences with light source.
7
90°
8
9
10
4x
90°
90
90°

Werbung

loading