Herunterladen Inhalt Inhalt Diese Seite drucken

Error Description; Liability Exclusion; Technical Data - SOLARA SR135TL Bedienungsanleitung

Solar-laderegler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Solar Charge Controller Solara SR135TL
User Manual English, Page 2
Low Voltage Disconnect Function (LVD)
The controller has 2 different modes to protect the battery from being deeply
discharged:
1. State of charge controlled: Disconnect at 11.4 V (at nominal load current) up
to 11.9 V (at no load current). Normal operation mode for good battery pro-
tection.
2. Voltage controlled: Disconnect at 11.0 V fixed setting. Appropriate if bypass
loads draw current directly from the battery.
The controller is preset to Mode 1 from the factory. Changing the mode setting is
described below.
In case of doubts which mode to choose, consult your dealer because this has to
be evaluated depending on the battery used.
Settings
The controller can be configured for special operation. For this purpose, open the
cover of the controller by removing the screws on the back side.
WARNING: The controller should not be opened while connected and in opera-
tion!
When the controller is opened, there are 3 jumpers on the electronic board:
3
1
With these jumpers, the following settings can be configured:
Jumper
GEL (1)
Function
Battery type
Setting jumper
Liquid
open
electrolyte
Setting jumper
GEL (VRLA
closed
battery)
Factory setting
Jumper open
(liquid electro-
lyte)
After completing the setting, replace the cover and tighten it with the screws.
Safety Features
The controller is protected against wrong installation or use:
At the solar termi-
nal
Battery connected
with correct
Unrestricted
polarity
Battery connected
Unrestricted
with wrong polarity
Yes, not at 24V
Reverse polarity
system voltage.
Short circuit
Unrestricted
Overcurrent
No protection
Thermal overload
No protection
No connection
Unrestricted
Reverse Current
Unrestricted
Overvoltage
Varistor 56 V, 2,3 J Max. 40 V
Undervoltage
Normal operation
WARNING: The combination of different error conditions may cause damage to
the controller. Always remove the error before you continue connecting the
controller!
2
For changing, put the jumper either
on both contact pins or only on one
contact pin:
Closed jumper
Open
jumper
LVD (2)
BUZ (3)
Function of low voltage
Acoustic alarm signal
disconnect
State of charge con-
Alarm off
trolled
Voltage controlled
Alarm on
Jumper open state-of-
Jumper closed
charge controlled
Alarm on
At the battery
At the load terminal
terminal
Normal operation
Unrestricted
Unrestricted.
Unrestricted
Acoustic Warning
Yes, if only the
Load output is
battery is connected.
protected. Loads
Acoustic Warning
might be damaged.
Unrestricted.
CAUTION: Battery
Unrestricted
must be protected
by fuse.
Controller switches
-----------------------
off load terminal.
Controller switches
-----------------------
off load terminal.
Unrestricted
Unrestricted
-----------------------
-----------------------
Controller switches
off load terminal.
Controller switches
Controller switches
off load terminal.
off load terminal.

Error Description

Error
Display
Loads are not
supplied
Battery is empty
after a short
time
Battery is not
being charged
during the day
Battery wrong
polarity
Permanent
sound
General Safety and Usage Recommendations
Intended Use
The charge controller is intended exclusively for use in photovoltaic systems with
12 V or 24 V nominal voltage and in conjunction with vented or sealed (VRLA) lead
acid batteries only.
Safety Recommendations
§ Batteries store a large amount of energy. Never short circuit a battery under all
circumstances. We recommend connecting a fuse (slow acting type, according to
the nominal controller current) directly to the battery terminal.
§ Batteries can produce flammable gases. Avoid making sparks, using fire or any
naked flame. Make sure that the battery room is ventilated.
§ Avoid touching or short circuiting wires or terminals. Be aware that the voltages
on specific terminals or wires can be up to double the battery voltage. Use iso-
lated tools, stand on dry ground and keep your hands dry.
§ Keep children away from batteries and the charge controller.
§ Please observe the safety recommendations of the battery manufacturer. If in
doubt, consult your dealer or installer.

Liability Exclusion

The manufacturer shall not be liable for damages, especially on the battery, caused
by use other than as intended or as mentioned in this manual or if the recommen-
dations of the battery manufacturer are neglected. The manufacturer shall not be
liable if there has been service or repair carried out by any unauthorized person,
unusual use, wrong installation, or bad system design.

Technical Data

Nominal voltage
12 / 24 V, automatic recognition
Boost voltage
14.5 / 29.0 V (25°C), 2 h
Equalization voltage
14.8 / 29.6 V (25°C), 2 h
Float voltage
13.7 / 27.4 V (25°C)
Low Voltage Disconnect
11.4-11.9 / 22.8-23.8 V controlled by state of
Function
charge
11.0 / 22.0 V controlled by voltage
Load reconnect voltage
12.8 / 25.6 V
Temperature compensation
-4 mV/cell*K
Max. solar panel current
8 A according to model number @ 50°C
Max. load current
8 A according to model number @ 50°C
Dimensions
80 x 100 x 32 mm (w x h x d)
Weight
180 gr
Max. wire size
16 mm² (AWG #6)
Self consumption
4 mA
Ambient temperature range
-40 to + 50 °C
Case protection
IP 22
Subject to change without notice. Version: SR135TL
Made in one of the following countries: Germany – China – Bolivia - India
SOLARA, Hamburg, www.solara.de
Reason
Remedy
Load will reconnect as
Battery is low
soon as battery is
recharged.
Switch off all loads.
Remove short circuit.
Overcurrent/ Short
Controller will switch
circuit of loads
on load automatically
after max 1 minute.
Check if other
Battery voltage too
sources overcharge
high (>15.5 / 31.0
the battery. If not,
V)
controller is damaged.
Battery wires or
battery fuse dam-
Check battery wires,
aged, battery has
fuses and battery.
high resistance
Battery has low
Change battery
capacity
Remove faulty con-
Solar array faulty or
nection/reverse
wrong polarity
polarity
Battery is con-
Remove reverse
nected with reverse
polarity
polarity

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für SOLARA SR135TL

Inhaltsverzeichnis