APPROPRIATE USE

The GAS ALARM GX-B1 is a gas warning device for city, natural and liquefied gases and can
already deliver a warning at a gas concentration that lies well below life-threatening values.
This monitoring system is, therefore, in line with its purpose, set to a very high sensitivity (see
table TECHNICAL DATA). The alarm is signalled acoustically and optically. The unit is suitab-
le for normal household use and may not be used in areas at risk of explosion.
Another use of the device as described above is not authorized.

TECHNICAL SPECIFICATIONS

Operating voltage:
Power consumption:
Operating temperature:
Protection type:
Acoustic pressure sounder:
Dimensions (HxWxD):
Data diagram Sensor
Gas type
CO
Methane
Propane (isobutane)
Ethanol (acetone)

INSTALLATION INSTRUCTIONS

The GAS ALARM GX-B1 may only be installed in dry, interior rooms and must be correctly
placed according to the type of gas to ensure faultless operation of the alarm system.
It is essential to observe the prescribed position of the alarm unit! For your
own safety and reassurance, please obtain information from your supplier
regarding their gas type and its properties!
230 (+/-10%) V AC / 50-60 Hz
approx. 1.5 W (stand-by)
-15°C / +40°C
IP 20
> 90 dB @ 10 cm
118x60x44 mm
Trigger point acc. to diagram
no alarm triggered
2500ppm (0.25%)
1000ppm (0.1%)
2500ppm (0.25%)
Minimum concentration
no alarm triggered
<0.5%
<0.2%
<0.5%