Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Assembly; Supra ® -Filter Internal With Straight Outlet - Garantia SUPRA Anleitung Für Einbau Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
4.1
SUPRA
-Filter internal with straight outlet
The SUPRA®-Filter Internal is prepared as shown
in the adjacent depiction.
The filter housing
is connected via the on site
installed canalisation pipe
well
(included in the SUPRA add on packet).
The couplings should be secured with commercial
self tapping screws.
Following this a 114 mm long inlet
and outlet pipe
as well as the
overflow siphon
are pushed in to
the Cristall underground tank until
the end stop position as shown in
the adjacent depiction.
Now the prepared SUPRA
internal is installed in the tank. The
inlet and outlet pipe have to be
positioned that it is flush with the
filter inlet and then finally fixed in
place with the quick assembly collar.
Under no circumstance may a mesh
barrier be installed in the outlet pipe
to prevent small animals entering the
tube. This will eventually lead to a
blockage from debris in the pipe.
info@garantia.eu
www.garantia.eu
4.

Installation and assembly

to the stabilising inlet
SUPRA-Filter
®
-Filter
internal
Inflow
1
2
L
114
Inflow
10 / 24
®
SUPRA
-Filter
with straight outlet
Pipe length with bush:
2650 L = 1100 mm
1600 L = 820 mm
(
all dimensions +/- 3% tolerance
3
settled inlet basked
Telescopic
dome shaft
114
Outflow
Siphon
Telescopic
dome shaft
Outflow
Siphon
internal
)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis