HOW TO ALIGN THE PHOTOCELL
Taking Fig. 6 as a reference, loosen screws E
so that the printed circuit C can be rotated.
Turn the circuit and align the transmitter with
the receiver. The correct alignment is shown
by the DL1 LED switching up on the receiver.
The transmitter sends a beam with narrow an-
gle. A perfect alignment is therefore required
on the entire stroke of the gate/door. Fig.7
shows the correct assembly of the device.
Fig.8 shows an incorrect assembly.
HOW TO REPLACE THE BATTERY
The transmitter is equipped with a recharge-
able battery at 2.4V 600mAh NiMH.
The battery lasts various years according to
the conditions of use.
When the DL2 LED starts flashing slowly, this
means that the battery is down.
Check the connection to the panel or recharge
it with a 2.6V 50mA recharger for at least 10
hours. If the battery stays down, replace it.
Use only original spare parts.
Taking Fig. 6 as a reference:
- remove the screws E and the board C
- the battery is at the back of the board (ref.
Tab.1 DIAGNOSTICS OF THE TRANSMITTER
Conditions of DL2 LED Description
Off
Slow flashing
Fast flashing
Tab.2 DIAGNOSTICS OF THE RECEIVER
Conditions of DL1 LED Description
Off
Fixed light
Fast flashing
1 flashing with interval
3 flashings with interval
4 flashings with interval
12
Normal operation
Battery down
Error in the safety edge
No signal from transmitter
Correct signal from transmitter
Correct signal from safety edge
Correct transmitter signal /
Error of safety edge
Faulty photocell relay
Both relays are faulty
Circuit off
I) and it is kept in the correct position by a
plastic box
- disconnect the battery and replace it. Recon-
nect the wire connections
- carry out a new alignment as shown in the
paragraph "How to align the photocell"
The batteries are special waste! Disposal
of the battery should be in compliance with
regulations in force

FINAL TEST

After connecting the control unit, the device
should undergo a final test:
- check that indicators related to the safety
edge and the photocell are correctly activated
in the control unit when the safety sensitive
edge is activated or the photocell beam is cut
off.
- carry out some trial operations by cutting off
the photocell beam and pressing the safety
edge. Check the correct operation of the door/
gate in all conditions of use.
Notes
Check the good conditions of the
battery and the connection of solar
panel
Check the good conditions of the
safety edge and the connection of
the contact
Notes
Check that photocells are correctly
aligned
Check the good conditions of the
safety edge and connections of the
contact
Cut off power supply and replace
the receiver
Check connection