Installation Instructions
Install the valve in seven easy steps—
1. Attach the Valves
2. Attach Sprinkler Lines
3. Run the Wire
4. Attach the Wire
1. Attach the Valves
After flushing lines, install the valve to
the manifold with an adapter or nipple
(adapter or nipple not required for Male
Jar-Top valve). DO NOT OVERTIGHTEN.
Do not use pipe joining compound.
Use thread seal tape only. Note arrow
for water flow direction. Valves have
tapered fittings and therefore require
seven to eight turns of thread seal
tape to prevent leaking and to guard
against the connections bottoming out.
To prevent possible leaking, make sure
that the manifold and pipe are properly
aligned.
2. Attach Sprinkler Lines
Attach sprinkler lines to valve with an
adapter (adapter or nipple not required
for Male Jar-Top valve).
RECOMMENDATION:
Use Orbit's Pre-Assembled Manifold to
make the valve easier to service or for
future manifold modifications.
3. Run the Wire
With the power off, connect the valves
to a an Orbit
timer (or any other timer
®
that uses a UL-approved 24-volt Class
2 transformer as a power source). Use
a multi-colored, multi-strand approved
jacketed sprinkler wire. Be sure the
wire has at least one more strand than
the number of valves in the manifold.
Run the wire to the valves (usually in
the same trench as the sprinkler pipe).
RECOMMENDATION:
Use a piece of PVC pipe as a protective
covering for sprinkler wire in areas of
frequent digging.
Draining
In freezing areas, the valves and lines will need to be drained.
Refer to the Orbit Layout Guide or local dealer to recommend proper drain points.
To insure the electric valve is completely drained in the fall, turn off the main
sprinkler shut-off valve and electrically run each valve dry for a few minutes. Turn
timer to the "OFF" position.
CAUTIONS:
Check local codes for valve types and
permit information.
If static water pressure exceeds
552KPa, a pressure regulator should
be used.
For outdoor use with cold water only.
Not for indoor use. Place valves so
they drain away from the house.
Troubleshooting for Inline Valves
It is rare that your Orbit
low voltage electric valve will not operate as it should.
®
If you do have any problems, try the following solutions.
Problem: The valve will not open electrically
First, run the valve manually by opening the manual bleed lever/screw (turn
counter-clockwise). Close the manual bleed lever/screw when manual test is
complete.
Check if...
Solution
1. The valve is installed
Make sure that the arrows are in the direction of
incorrectly
water flow.
2. Wiring is incorrect
Check wiring at the valve and at the timer with
the instructions Check to see that timer is
working properly.
3. There is debris
Turn off water. Remove the solenoid.
in the port hole
Push a wire or large paper clip down through the
round port hole working it up and down to free
any debris. Be sure the plunger and O-ring are in
place when reassembling.
4. Defective solenoid
Turn off water. Unscrew the solenoid and replace
with one from a working valve. If the valve works,
replaces the solenoid. Be sure the plunger and
O-ring are in place when reassembling.
5. Solenoid plunger
Turn off water. Remove the solenoid and clean out
is stuck
sand and debris. Be sure the plunger and O-ring
are in place when reassembling.
Problem: The valve will not close
Check if...
Solution
1. The valve is installed
Make sure that the arrows are in the direction of
incorrectly
water flow.
2. Solenoid plunger is stuck
Turn off water. Remove the solenoid and clean
out sand and debris. Be sure the plunger and
O-ring are in place when reassembling.
3. Rock or debris is
Turn off water. Remove valve lid and diaphragm
between the washer and
assembly and clean the interior of the valve.
the valve seat
4. Diaphragm has ruptured
Turn off water. Remove the lid and inspect the
diaphragm for tears. Replace the diaphragm
assembly if torn.
Problem: External valve leaks
Check if...
Solution
1. PVC fittings going into
Use thread seal tape generously on threads and
valve installed incorrectly
tighten firmly. Do not over tighten.
2. Pressure is too high
Install a pressure regulator upstream of the valve
and set at about 552KPa.
3. Leaking below solenoid
Turn off water. Tighten solenoid.
Orbit
Irrigation Products, Inc.
®
845 North Overland Rd.
North Salt Lake, UT 84054 USA
www.orbitonline.com
801-299-5555
1-800-488-6156
ENGLISH
5. Close the Sprinkler Valves
6. Test the System
7. Open the Valves
4. Attach the Wire
Attach a colored wire to one valve wire
on the solenoid and a common wire
to the other wire on the solenoid. It
doesn't matter which solenoid wire
you use as the common. Attach the
colored wires to the corresponding zone
terminal in the timer and the common
wire to the common connection in the
timer. Use standard 20 gauge sprinkler
wire for distances less than 244 m. Use
18 gauge wire for distances over 244 m.
Use an Orbit
grease cap and wire nut
®
at each valve connection (See Figure
A ). Also, waterproof any splices made
along the sprinkler wire.
5. Close the Sprinkler Valves
Turn the manual bleed lever clockwise
until closed. When the water is turned
on, the valve will remain closed.
6. Test the System
After all pipe and fittings have been
installed, turn the water supply on and
check for leaks with the valves closed.
7. Open the Valves
Turn the manual bleed lever/screw
counterclockwise to manually open
the valve. Then close the manual bleed
lever/screw to shut the valve off. The
system is now ready to be controlled
electrically from the timer or manually
by opening the manual lever/screw.
NOTES:
Where possible, always protect valves
with an Orbit Valve Box and place
gravel in the bottom.
Test all lines and fittings before
burying the system.
Use a filter if you will not be using
culinary water in your system.
96150-24 Rev B
User Guide
Jar Top Automatic In-Line
Control Valve
Guía del usuario
Válvula de control automática
en línea Jar Top
Guide de l'utilisateur
Vanne automatique en ligne
Jar Top
Manuale dell'utente
Valvola di comando in linea
automatica superiore
Bedienunganleitung
Jar Top Automatisches Inline
Ventil
Instructions for Operation
Instrucciones para el funcionamiento
Mode d'emploi
Istruzioni di funzionamento
Betriebsanleitung
Automatic In-Line Control Valve is a 25 mm or 20 mm (24-volt) versatile valve
La válvula de control automática en línea es una válvula versátil de 25 mm ó 20 mm pulg. (24
volt)
La vanne automatique en ligne est une vanne polyvalente de 25 mm ou 20 mm (24 V)
La valvola di comando in linea automatica è una valvola versatile da 25 mm o 20 mm (24 volt)
• Always check local codes before installing any sprinkler system.
• Arrow indicates direction of water flow.
• If static water pressure exceeds 552KPa, a pressure regulator should be used.
Figure A
Common Wires Out to Valve (Colored Wires)
To Timer
Grease Cap
Common Wire
Out to Timer
(Usually White Wire)
Main Sprinkler
Water Line
Valve Parts
Friction Loss Chart
For In-Line Valve
Gráfica de perdidas por fricción
para válvula en línea
T ableau des pertes de charge par frottement
des vannes en ligne
Diagramma della perdita per attrito
Per valvola in linea
Reibungsverlust Chart
Bei Reihenventilen
9
8
7
6
5
4
3
2
1
5
10
15
20
25
30
Flow Rate - GPM
Velocidad de flujo - GPM
Débit (gal/min)
Velocità del flusso - GPM
Durchflußrate - GPM
Electrical requirements are 18 Volts AC minimum at
the solenoid.
Inrush volt-amps
@24 VAC - 8.5 VA
Inrush current
@24 VAC - .35 AMPS
Holding volt-amps
@24 VAC - 5.5 VA
Holding current
@24 VAC - .23 AMPS
MODEL NUMBERS
NÚMEROS DE LOS MODELOS
NUMÉROS DE MODÈLE
VERSIONI DEL MODELLO
MODELLNUMMERN
57471, 57467, 57461, 57477,
94150, 94151, 91150,
Virtual Rain Model 27671
To Sprinkler Heads
Solenoid
Solenoid Plunger
Solenoid O-Ring
Internal Bleed lever
Ring
Bleed Screw
Valve Lid Assembly
Spring
Diaphragm Assembly
S.S. Tube
Diaphragm Support Ring
Valve Body
Se requiere un voltaje de 18 Volts CA como mínimo
en el solenodie
Volt-amps de entrada
@24 VAC - 8,5 VA
Corriente de entrada
@24 VAC - 0,35 AMPS
Volt-amps de retención
@24 VAC - 5,5 VA
Corriente de retención
@24 VAC - 0,23 AMPS
des vannes
Caractéristiques électriques minimales: 18 V c.a. au
solénoïde.
Puissance d'appel
@24 VAC - 8,5 VA
Courant d'appel
@24 VAC - 0,35 AMPS
Puissance de maintien
@24 VAC - 5,5 VA
Courant de maintien
@24 VAC - 0,23 AMPS
Requisiti elettrici: minimo 18 V CA al solenoide.
Corrente massima di
@24 VAC - 8,5 VA
funzionamento (VA)
35
Corrente massima di
@24 VAC - 0,35 AMPS
funzionamento (A)
Corrente minima di
@24 VAC - 5,5 VA
funzionamento (VA)
Corrente minima di
@24 VAC - 0,23 AMPS
funzionamento (A)
Anschlußwerte: min. 18 V ~ am Elektromagneten
inschaltspitze Volt-Amp.
@24 VAC ~ - 8.5 VA
Einschaltstromspitze
@24 VAC ~ - .35 AMPS
Haltestrom Volt-Amp.
@24 VAC ~ - 5.5 VA
Haltestromt
@24 VAC ~ - .23 AMPS

Werbung

loading

Inhaltszusammenfassung für Orbit Jar Top

  • Seite 1 In freezing areas, the valves and lines will need to be drained. Refer to the Orbit Layout Guide or local dealer to recommend proper drain points. To insure the electric valve is completely drained in the fall, turn off the main sprinkler shut-off valve and electrically run each valve dry for a few minutes.
  • Seite 2 SPANISH FRANCAIS • Always check local codes before installing any sprinkler system. • Always check local codes before installing any sprinkler system. • Arrow indicates direction of water flow. • Arrow indicates direction of water flow. • If static water pressure exceeds 552KPa, a pressure regulator should be used. •...
  • Seite 3 En áreas muy frías, las válvulas y los conductos necesitarán drenarse. Consulte pour s’assurer que l’électrovanne est complètement purgée, fermez le robinet la guía de distribución Orbit o a su proveedor para que le recomiende los puntos principal des aroseurs et faites fonctionner électrique ment chaque vanne, à sec, de drenaje adecuados.
  • Seite 4 Ricerca guasti per valvole in lines Gebrauch in geschlossenen Räumen. Einsatz eines Filters. Stellen Sie die Ventile so ein, daß È raro che l’elettrovalvola di bassa tensione del Orbit non funzioni in modo ® Sie nicht in Richtung zu Gebäuden corretto, ma in caso di problemi, provare quanto segue.

Diese Anleitung auch für:

574675746157477574719115094150 ... Alle anzeigen