SSS Siedle DRM 611-01 Bedienungsanleitung Seite 18

Display-ruf-modul

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
Application
Display call module as an input unit
with a 4­line display for placing door
calls. The call controller RC 602­... is
only required when the 1+n technik
is used.
Customer­specific data stored in
the DRM 611­... is indicated on the
display. To scroll through the name
index, there are two arrow keys pro-
vided for "up/down".
If the required name is highlighted
in the name list, this user will be
called when pressing the bell symbol
button.
An external DR button can be con-
nected.
The DRM 611­... can also be used in
combination with the COM 611­...
in order to display the input via the
DRM 611­...
• Display showing 4 lines of 18 char-
acters each, with LED backlighting
• 3 piezo buttons displacement­free
• Button actuation with acoustic
confirmation
• Illuminated symbols
• In the Siedle In­Home system, the
BIM 650­... is required
• Up to max. 504 users can be pro-
grammed
Programming possibilities:
• Using the call controller card
RCC 602­...
• Using a PC and the Vario bus pro-
gramming software PRS 602­... via
programming interface PRI 602­...
• or manually using the 3 buttons at
the DRM 611­...
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
• In order to comply with the gen-
eral safety regulations for telecom-
munication systems in accordance
with VDE 0100 and VDE 0800, and
to prevent electrical interference,
ensure separate routing of heavy
and light current conductors. A dis-
tance of 10 cm must be adhered to.
18
• In order to place door calls in the
1+n system, a call controller
RC 602­... and where applicable sev-
eral call controller extensions
RCE 602­... are required.
• In the Siedle In­Home system, the
call controller is required if data has
to be loaded via the call controller
card.
• In the Siedle In­Home system, the
BIM 650­... is required.
• In the Multi system, ensure that
the software used in the TLC 640­...
is version 71.08 or later.
Pilfer safeguard
In order to protect the Vario modules
from unauthorized access, the pilfer
safeguard controller DSC 602­... can
be optionally used in conjunction
with the ZDS 601­... This can be
used to protect the inserted modules
from unauthorized access.
Range
The conductor network laid for
the whole of the Variobus may not
exceed a length of 2000 m.
The loop resistance (forward and
return line between the DRM 611­...
and the RC 602­...) must not exceed
20 Ohm. With a core diameter of
0.8 mm, this results in a range of
appr. 250 metres. The power supply
to the Variobus components is pro-
vided via a separate transformer
TR 602­...
Steps must be taken to ensure that
the supply voltage never falls below
9 V/AC at any time at maximum cur-
rent input to each device.
Certain ranges between the door
loudspeaker and line rectifier /
between the door loudspeaker
and in-house telephone must
be observed in conjunction with
Siedle door intercom systems. For
more details, refer to the Door and
In­house Telephony Planning and
Installation Guidelines.
Conductor material
Telecommunication cables must be
used for installation on the bus side
J-Y(St)Y
Twisted­pair con-
ductors, shielded,
0.8 mm core
diameter
A-2Y(St)2Y
Telecommunication
cable 0.8 mm core
diameter
Mounting
1 Address setting
• Open the flap on the back of the
module with the aid of a screw­
driver.
• Set the address (1 to 8) at the
rotary switch.
• After setting the address, close
the flap. The module is ready for
installation.
An address may only be assigned
once to any connected DRM 611­...
unit in the system.
2 Plug in the ribbon cable with com­
bination terminal
3 Insert the DRM 611­... in the
mounting frame
4 a Terminal diagram at the 1+n
system. The default numbers are set
from 1 to 504 and correspond to
the physical assignment at the RC/
RCE 602­... 7.1, 7.2 etc.
4 b Terminal plan at the Siedle
In­Home system
4 c Terminal plan Siedle Classic
Terminal assignment
bv, cv
Supply
Da, Db
Data lines
E1, E2
for external door release
button
6, 1
Triggering Door
loudspeaker
Specifications
Operating voltage: 12 V AC
Operating current: max. 200 mA
Protection system: IP 54
Ambient temperature:
­20°C to +55°C
Dimensions (mm) W x H x D:
99 x 99 x 27