Herunterladen Diese Seite drucken
Fujitsu MCD3130SS Installationsanleitung
Fujitsu MCD3130SS Installationsanleitung

Fujitsu MCD3130SS Installationsanleitung

Magnetooptisches plattenlaufwerk

Werbung

MCD3130SS
Magneto-Optical Disk Drive
Installation Guide
Installationsanleitung
Guide d'installation
© COPYRIGHT FUJITSU LIMITED
JAN. 1999
C156-E096-01XA
This guide is prepared to instruct the user on the switch and jumper
settings in the MCD3130SS when you install your MCD3130SS.
Note; Factory default settings are marked with .
Layout of PCA
SCSI ID Setting
Table 1
SCSI ID
SW1-01 SW1-02 SW1-03
Not
used
0
Off
Off
Off
1
Off
Off
On
GND
+5V
2
Off
On
Off
DC
3
Off
On
On
SCSI
4
On
Off
Off
Pin 50
5
On
Off
On
6
On
On
Off
7
On
On
On
SCSI
Pin 2
SW1 AND CNH2 SETTINGS
Switch 1 sets the SCSI ID and some drive functions and CNH2 sets
additional drive functions.
SW1
Key#
Function
Key on
Key off
01
————
————
02
SCSI ID (see table 1 above)
03
04
SCSI data bus parity check
Enabled
Disabled
05
Write cache mode
Enabled
Disabled
06
Device type mode
MO
Fixed Disk
07
Spindle automatic stop mode
Enabled
Disabled
08
Factory test (Not to be set by user)
Enabled
Disabled
CNH1 (TERMINATING POWER AND SCSI TERMINATION)
Terminal CNH1 uses shorting bars to set the power source and to
enable or disable SCSI termination.
Pin# Function
Short
Open
Power supplied by
1–2
3–4
1–2
Power supplied by Supplied Not
Drive
Short Open
drive
supplied
Host controller
Open Short
3–4
Power supplied by Supplied Not
Drive and Host
Short Short
host controller
supplied
controller
5–6
SCSI termination
Enabled
Disabled
enabled
CNH2 (EXTERNAL SWITCH
OPERATOR PANEL
SETTING)
1
TTL-IC
2
3
Pin#
Function
Open
Short
4
1
Cartridge-in detection
5
2
SCSI ID 4
3
LED source (+5 V)
6
4
SCSI ID2
7
5
LED source (–)
8
6
SCSI ID1
9
7
Signal to eject cartridge
10
8
Ground
11
9
Device type mode
Fixed disk
MO
12
10
SCAM mode
Disabled
Enabled
11
Write verify mode
Enabled
Disabled
13
12
Ground
14
13
Macintosh mode
Disabled
Enabled
15
14
SCSI type 0
SCSI 2
SCSI 1
16
15
Terminating resister mode
Disabled
Enabled
0V
16
Ground
Note: The cable length must not exceed 30cm.
Device Driver
You need to install Fujitsu's device driver to avoid the 2KB sector
problem in Windows9x and the OS-timeout-problem in Windows9x and
NT3.51/4.0.
MCD3130SS HANDLING AND MAINTENANCE
Orientation
Cleaning lens and media
The drive can be installed in one
recommendation
of three orientations; either PCA
Clean the lens on the drive head
up or on either side edge.
and the disk media once every
three months. More frequent
Ejecting cartridge
cleaning may be required in a
Cartridges can be ejected by
dirty environment. Use the
pressing the eject key or by a
Fujitsu head cleaning kit and
SCSI eject command. Never
media cleaning kit.
Head
eject a cartridge mechanically
Cleaning kits from other vendors
except in an emergency.
will not work.
WORLD WIDE WEB SITE
Corporate http://www.fujitsu.co.jp/
SINGAPORE http://www.fujitsu-computers.com.sg/
USA
http://www.fcpa.com/
CANADA
http://www.fujitsu.ca/
EUROPE http://www.fujitsu-europe.com/
AUSTRALIA http://www.fujitsu.com.au/

Werbung

loading

Inhaltszusammenfassung für Fujitsu MCD3130SS

  • Seite 1 Key off Device Driver ———— ———— SCSI ID (see table 1 above) You need to install Fujitsu's device driver to avoid the 2KB sector problem in Windows9x and the OS-timeout-problem in Windows9x and SCSI data bus parity check Enabled Disabled NT3.51/4.0.
  • Seite 2 (siehe Tabelle oben) ———— ———— Vous devez installer le pilote de périphérique Fujitsu pour éliminer le (Voir tableau 1 ci-dessus) Es ist notwendig, daß Sie den Fujitsu-Gerätetreiber installieren, um das problème de secteur de 2Ko sous Windows 9x et le problème de délai 2KB-Sektorenproblem unter Windows 9x sowie das OS-Timeout- Parité...