Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - Hydrofarm Autopilot APCET Anleitung

Analog 24hr day & night cooling/heating thermostat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Q&A
How can I tell if the photocell is working?
There is a built-in 20 second time delay for the photocell to change status. A green LED on the top
RIGHT edge of the unit that says "Daytime" will light up when the photocell is in Daytime mode.
Can I connect more than one device to the unit?
Yes, as long as the total amperage of the devices connected to the unit do not exceed the maximum
rating of the unit. We recommend the total amps not to exceed 75% of the rating.
The temperature of the area does not seem to be correct.
The sensor is located on the bottom on the unit in the protective plastic "cage." Ensure the unit is not
being affected by other factors such as direct sunlight exposure or areas that may not have good air
movement.
What if there is no power?
Ensure the unit is getting power. Check the device that is connected to the unit by plugging it directly
into a known power supply. If the unit will not turn on and no LEDs will illuminate, contact your
distributor for repair and warranty issues.
Why are the red and yellow LED lights blinking and no power?
The blinking lights tell user the unit is in overcurrent protection mode. It may be caused by large load
current. Please unplug the unit and plug in again to resume the normal operation. If the user does not
re-plug the unit, it will attempt to re-power itself after 10 minutes. After the error is reset, the unit will
resume normal operation.
Temperature control range
Separate Day & Night settings
INSTRUCTIONS

SPECIFICATIONS

Input voltage
Maximum amperage
Temperature accuracy
Temperature deadband
(hysteresis)
Weight
Dimensions
120 VAC
14.5A @ 120 VAC
45° to 95°F
photocell control
+/- 5°F
3°F
< 1 lb
3" x 6" x 3.5"