Step 1
Step 1
• Place the outdoor fountain (6) on a flat, secure and horizontal surface. The mains
cable must be fed through the opening on the side of the fountain. Plug the
connector on the mains cable into the connection socket on the mains plug (7).
Screw the union nut in place.
Do not connect the mains plug to the mains socket. This will be done later.
Step 2
• Connect the connector plug (3) to the socket (4). Secure the connection using the
union nut on the connector plug.
• Place the water hose nozzle onto the opening on the pump (5).
• Place the pump on the bottom of the outdoor fountain. Pour clean, clear water
through the opening above. Pay attention to the water level markings for the
minimum water level MIN and the maximum water level MAX inside the fountain.
The water level must always be between the MIN and MAX markings.
• The decorative ball (2) and the LED unit (1) are firmly attached to each other. Place
the decorative ball onto the outdoor fountain with the LED unit facing upwards.
Carefully turn the decorative ball until it sits securely in the opening on the outdoor
fountain. Do not use any force to prevent damage to the product.
Step 3
• Place the mains plug into a suitable outdoor socket (IP44). The pump starts working
immediately and the white LEDs turn on. The water is pumped upwards through the
opening in the middle of the LEDs and flows over the decorative ball back into the
fountain.
Ensure that the cable is placed in a
drip loop. This prevents water from
flowing along the power cable to
the mains socket. This constitutes a
risk of a fatal electric shock!
• Remove the mains plug from the mains socket after use. The pump stops immediately
and the LEDs turn off.
Setting the flow volume
Disconnect the pump from the power supply. You can set the desired water flow
volume using the slide switch on the front on the pump. Move it towards "+" to increase
the flow volume. Move it towards "-" to decrease the flow volume.
1 LED unit
2 Decorative ball
3 Connector plug
4 Socket
5 Pump
6 Outdoor fountain
7 Mains plug
Step 2
Step 3
To the
pump
Drip loop

Troubleshooting

Problem
The pump does not deliver any
water or is noisier than usual.
The pump does not deliver enough
water.
There is air in the pump.
Maintenance and cleaning
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as
these could damage the housing or even impair the functioning of the product.
• Always unplug the mains plug from the mains socket before cleaning.
• Change the water every three days. If possible, use clear, purified water.
• Remove coarse dirt and clean the fountain. Use protective gloves to prevent injuries.
• If dirt has accumulated in the pump inlet, disconnect the pump from the mains.
Remove the dirt and rinse the pump with clean, flowing water.
• Pay attention to the storage conditions in the Technical data. Empty the water. Store
the product in a frost-proof room as soon as the outdoor temperature drops to a
level where there is a risk of frost.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of
the environment.
Technical data
a) Outdoor fountain and pump
Operating voltage/current .................12 V/AC, 50 Hz (pump)
Power consumption............................max. 7 W (pump)
LED.........................................................6 x LED (white), 0.125 W each
Colour temperature.............................6000 - 7000K
Protection type ....................................IPX8
Protection class ..................................III
Water volume ......................................7.5 to 22 l
MIN water level marking. ..................7 cm
MAX water level marking. .................26 cm
Pump head ...........................................max. 0.95 m
Water temperature .............................+1 to +35 °C
Operating conditions ..........................+1 to +35 °C, 0 - 90 % RH
Storage conditions..............................+1 to +35 °C, 0 - 90 % RH
Mains cable length .............................approx. 5 m
Dimensions (W x H x D)......................380 x 710 x 315 mm (outdoor fountain)
Weight ...................................................approx. 5.9 kg (outdoor fountain with pump)
b) Power adapter
Input voltage/current..........................230-240 V/AC, 50Hz, 70 mA
Power consumption............................max. 11 W
Output voltage/current .......................12 V/AC, 1 A
Protection type ....................................IP44
Protection class ..................................II
Weight ...................................................610 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
Suggested solution
There is not enough water in the container.
Remove the power adapter from the mains
socket. Fill the fountain with clear water to
at least the MIN mark but not higher than the
MAX mark. Plug the mains plug back into the
mains socket.
Increase the water flow volume (see "Setting
the flow volume").
Unplug the pump and disconnect the power
adapter from the mains. Pour water into the
tube from above. Plug the pump back in and
insert the mains plug into the mains socket.
V3_0415_02-HK

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1300046

Inhaltsverzeichnis