Herunterladen Diese Seite drucken

adpro PRO E-18W Anleitung Seite 2

Werbung

Opening of housing bracket
Filter (window)
Bracket cover
Removal from mounting surface
tamper contact adjustment screw
Rotary switch position-detector model mapping
Pin
Model
Description
1
PRO E-45
2
PRO E-18W
3
PRO E-18
4
PRO E-30
5
PRO E-40
6
PRO E-45D
7
PRO E-100
8
PRO E-85
9
PRO E-51
A
PRO E-45H
with heater
Note: shipped detector is already pre-set to correct
model. Do not change.
B
PRO E-18WH
with heater
C
PRO E-18H
with heater
D
PRO E-45DH
with heater
E
PRO E-100H
with heater
F
PRO E-85H
with heater
Opening of housing
Housing cover
360PROtect
TM
lens
Bead
Masking Detection lenses
Notch
Locking screws
Compliant seal
Pin
Function
Description
1
GND
GND supply
2
+
V+ supply voltage
3
RS-485 - B
RS-485 bus
4
RS-485 - A
5
OUT 5
free programmable
output 5
(for H-versions)
6
OUT 5
7
OUT 4
free programmable
output 4
(for H-versions)
8
OUT 4
9
ALARM
alarm output
10
ALARM
11
AE
end-of-line alarm
12
FAULT
fault alarm output
13
FAULT
14
TAMPER
tamper alarm output
15
TAMPER
16
TE
end-of-line tamper
Application of iCommission on swivel bracket
Telescopic sight mounting block
(comes with alinment telescope)
iCommission
Pin assignment and output event selection
Settings
10.5 - 30 V
, 24 V
±15% auto-sensing
DC
AC
Following events lead to alarms listed in the table, which can be disabled/enabled via ADPRO PRO E-TOOL-Software (DEFAULT setting = bold italic underlined):
• masking detection (instead of `ALARM´+´FAULT´)
• alarm (IR)
• alarm_medium range (IR); alarm_long range (IR), alarm_short range (IR)
*)
• alarm creep zone channel 1 (CH1), creep zone alarm channel 2 (CH2)
• tamper alarms (cover open, detector alignment, bracket tamper contact
• hardware information (e.g power failure)
• info alarms (pulse count near, pulse count far, power on)
*) multi-channel detectors only
• masking detection (instead of `ALARM´+´FAULT´)
• alarm (IR)
• alarm_medium range (IR), alarm_long range (IR), alarm_short range (IR)
*)
• creep zone alarm per channel
• tamper alarms (cover open, detector alignment, bracket tamper contact
• hardware information (e.g. power failure)
• info alarms (pulse count near, pulse count far, power on)
*) multi-channel detectors only
• alarm (IR)
• alarm_medium range (IR), alarm_long range (IR), alarm_short range (IR)
*)
• alarm creep zone (CH1+CH2) - non-H-versions
• masking detection (together with intrusion FAULT)
• power on
*) multi-channel detectors only
support point for end-of-line cabling; refer to Fig. „Terminal block and pin assignments"
• power failure
• masking detection (together with intrusion ALARM) - non-H-versions
• heat system error - H-versions
• fl ash problems
• wrong model selected; refer rotary switch mapping
• power on
• cover open
• alignment
• tamper contact of mounting bracket
support point for end-of-line cabling; refer to pin assignment
Terminal block and pin assignments
16
15
14
13
12
R
end-of-line
cabling
Side covers w/ breakout cuts
for hose clamps
Recommended fi xing
8 mm
d
0
h
50 mm
1
L
40 mm
D
4.5 - 5 mm
d
S
d
47 mm
bracket guide
L
90 mm
S
F
2 Nm
A
B
11
10
9
8
7
6
5
4
3
2
1
R
end-of-line
cabling
Drilling holes dimensions
36 mm
5 mm
5 mm
L
S
F
d
d
0
s
d
L
bracket guide
D
h
1

Werbung

loading

Diese Anleitung auch für:

Pro e-45Pro e-30Pro e-40Pro e-18Pro e-100Pro e-45d ... Alle anzeigen