Installation
11. Before installation
1 Clean the area thoroughly before installation, no dust or debris can be
!
aspirated.
2 The exhaust hose must not be routed together with gas pipes, hot-air
pipes, etc. through a chute.
3 The exhaust tube should be as straight as possible carried away from the
cover and guided at a maximum deflection of 120 ° towards the outside
and secured to the outer wall.
4 In order to avoid accumulations of fat in a corner, make sure when instal-
ling that the hood is suspended horizontally.
11.1 Operation modes
Exhaust air mode
Without carbon filter
!
Please see installation specifica-
tion in chapter 7.1.
Circulating air filter mode
Same procedure
as described un-
der the following
chapter B. Howe-
ver, omit step 2.
In addition fit the
carbon filter(s)
A2 before moun-
ting the grease
filter (Fig. A1)
35 35