Inhaltsverzeichnis Allgemeine Hinweise LUX METER / LIGHT METER Technische Daten Messablauf LUX MULTIMETER Technische Daten Betriebsanleitung QUANTUM LIGHT METER Technische Daten Betriebsanleitung Basisinformationen Quantitative Bewertung von Strahlung / Licht Tabellen für Sonnenlicht in Lux 5.2.1 Beispiele für Beleuchtungsstärken 5.2.2 Einfluss von Abdeckungen auf Beleuchtungsstärken 5.2.3 Abhängigkeit des Pflanzenwachstums von der Beleuchtungsstärke –...
Seite 3
Table of Contents General Information LUX METER / LIGHT METER Technical Specifications Operating instructions LUX MULTIMETER Technical Specifications Operating instructions QUANTUM LIGHT METER Technical Specifications Operating instructions Basic overview Quantitative valuation of radiation / light Tables for sunlight in Lux 5.2.1 Examples of lighting levels 5.2.2 Influence of illumination on covers 5.2.3 Dependence of the plant growth of the light level –...
Stand anzupassen. Das Ver Bedienungsanleitung beschrieben ist. Um vielfältigen und Verbreiten der Betriebsan zusätzliche Gefährdungen zu vermeiden, leitung oder Auszügen hiervon, auch in dürfen keine unbefugten Veränderungen am übersetzter Form, bedarf einer schriftlichen Gerät vorgenommen werden. Der Austausch Genehmigung. Gerätekomponenten...
Seite 5
Entsorgung Elektronische Altgeräte sind Wertstoffe und dürfen nicht über den Hausmüll entsorgt werden. Entsorgen Sie das Gerät am Ende seiner Lebensdauer nach den geltenden gesetzlichen Vorschriften bei den kommunalen Sammelstellen oder senden Sie das Gerät nach Ende der Nutzungszeit direkt an uns.
Bedienelemente und Anschlüsse am Gerät LUX METER/ LIGHT METER 3½stellige LCDAnzeige mit Batteriezu 2.1 Technische Daten standsanzeige Ein/Aus und Funktions/Bereichswahl TECHNISCHE DATEN: schalter zur Anwahl sämtlicher Funktionen Messbereiche: 0 – 200/2.000/20.000/50.000 lx c Fotosensor: langlebige SilikonFotodiode 20.000 LuxBereich: Anzeige x 10 mit Filter 50.000 LuxBereich: Anzeige x 100 (kalibriert mit 2.856 K Standard Glühlampe)
Typ IEC 6F22 c HoldFunktionstaste oder Typ 006P d Umschaltung zwischen Lux (lx) und Foot Abmessung Sensor: 55 x 85 x 12 mm (B x H x T) Candle („FC“ in ftcd) Geräteabmessung: 72 x 180 x 32 mm (B x H x T) ...
Widrige Umgebungsbedingungen sind: übertragen und je nach Schalterstellung, Lux Nässe oder zu hohe Luftfeuchtigkeit oder ftcd, am Display angezeigt. Durch den Staub und brennbare Gase, Dämpfe oder externen Sensor werden somit bequeme Lösungsmittel Punktmessungen ermöglicht. Betrieben wird starke Vibrationen das Messgerät von einer handelsüblichen...
Seite 9
(Verschlusskappe) wieder. wählen Sie den nächst niedrigeren Bereich. Achtung!!! Ab einer „Gehäusetemperatur“ d) Positionieren Sie den Sensor möglichst direkt von ca. +60°C kann es vorkommen, dass das unter die Lichtquelle und lesen Sie die gesamte Anzeigenfeld „schwarz“ und damit Beleuchtungsstärke ab.
Seite 10
Batteriewechsel und eine gelegentliche gehalten. Gleichzeitig erscheint das Symbol Reinigung des Gehäuses, des Sensors und „D:H“ in der Kopfzeile des Displays. Um des Displayfensters wartungsfrei. Zur Reini die Holdfunktion zu verlassen bzw. um gung des Gerätes nehmen Sie ein sauberes, zur laufenden Messung zurückzukehren,...
Seite 11
rodieren können und dadurch Chemikalien frei setzen, welche Ihrer Gesundheit schaden bzw. das Batteriefach zerstören können. Verbrauchte Batterien gehören nicht in den normalen Restmüll. Sie sind als Sondermüll zu betrachten und müssen daher um weltgerecht entsorgt werden. 2. Anschluss des Lichtsensors Dem Messgerät liegt ein Lichtsensor mit Abdeckung bei.
QUANTUM LIGHT METER 4.2 Betriebsanleitung 4.1 Technische Daten Bedienung 1. Den Drehschalter auf „On“ stellen. TECHNISCHE DATEN: 2. Das Messgerät senkrecht halten, so dass der 0 – 1.999 µmol/m²s Messbereich: Sensor an der Geräteoberseite genau waa ± 5% gerecht positioniert ist. Messgenauigkeit: LC Display Anzeige:...
Seite 13
Strahlungsquellen Natriumdampf Leuchtstoff/ Halogen Sonnenlicht Hochdrucklampen Fluoreszenzlampen Metalldampflampen Anzeige QUANTUM LIGHT METER multipliziert mit 0,92 0,94 Wellenlänge (nm) Abb. 5: Abhängigkeit der Empfindlichkeit des QUANTUM LIGHT METER von der Wellen länge Umrechnungen Durch Multiplikation mit 10,2 ergibt sich der Wert in Foot Candle. Durch Multiplikation mit 104 ergibt sich der Wert in Lux.
General Information Make sure that you operate the device only within the specific limits defined by the tech LUX METER/ LIGHT METER, LUX nical specifications. MULTIMETER, QUANTUM LIGHT METER This device may not be used in ignitable or These operating instructions describe the explosive atmospheres! installation, operation and maintenance procedures for the aquired light meter.
Seite 15
You may also send the device directly to us. We will make sure that it is disposed of properly in an environmentally friendly manner.
Power supply: 1 x 12volt, size A23 Replacing the battery Dimensions of photo sensor: 60 x 115 x 27 mm (W x H x D) The battery must be replaced when the BAT symbol illuminates. Dimensions of meter: 64.5 x 188 x 24.5 mm (W x H x D) Switch off the meter.
006P Save button (Min/Max/Average values) Dimensions of sensor: 55 x 85 x 12 mm (W x H x D) Memory button used to display the Min (min Dimensions of meter: 72 x 180 x 32 mm (W x H x D)
illumination strength for your special Sensor socket port (on meter) application. Battery cover (on bottom of housing) You can select the type of light: sunlight, incandescent bulb, fluorescent lamp, 3.2 Operating Instructions highpressure sodiumvapour lamp, high pressure mercuryvapour lamp. The The LUX MULTIMETER should be used pro...
Seite 19
Turn the range dial to 2,000 lx (or 200 ftcd). lowest range. c) Press the “zeropoint” button once – this dis d) Place the sensor directly under the light play will show the number 0. Now remove the source and read the illumination strength sensor cover.
Seite 20
4. Using the “SAVE” function operating position The SAVE button (record function) is used to 1. Battery replacement start recording measurements; the minimum The meter uses a 9volt battery to ensure (MIN), maximum (MAX) and average (AVG) proper functioning. Replace the battery as values that occur during the interval are soon as the “LBT”...
(PPFD) where the unit is µmol/m Dimensions and weight: 5. Turn off the Quantum meter after you are 75 x 150 x 27 mm (W x H x D), 130 g done using it. Battery replacement The QUANTUM LIGHT METER requires a standard 9volt battery (6LR61).
Radiation sources Highpressure Luminescent / fluores Halogen Sun light sodiumvapour lamps cent lamps metalvapour lamps QUANTUM LIGHT METER display multiplied by 0,92 0,94 Figure 5: Wavelength (nm) The sensitivity of the QUANTUM LIGHT METER in relation to the wavelength Conversion factors Multiply by 10.2 to determine the foot candle value.
• Die photometrische „Beleuchtungsstärke“. µmol ist ein Zahlenfaktor 1µmol = 6 x 10 Sie erfasst die Wirkung auf das menschli che Auge, d.h. den Helligkeitseindruck ei Messung mit einem Quantum-Meter ner beleuchteten Fläche für Menschen. Das menschliche Auge kann Strahlung im Wel...
Typische Werte von Beleuchtungsstärken Basic overview gibt die Tabelle S. 32 wieder. 5.1 Quantitative analysis of radiation/ light Für Pflanzen werden je nach Pflanzensorte und Wachstumszustand unterschiedliche The entire electromagnetic radiance that PPFDWerte angegeben. Meist liegen die radiates on a surface is referred to in physics Wer te im Bereich um 50 µmol/m²s, bei Keim...
Seite 25
• The “photosynthetically Active Photon Flux Different PPFD values are specified for differ Density (PPFD or simply PFD)”:The photo ent plant types depending on the plant type synthesis takes place as photons (light quan and state of growth. Most of the values are tum) are absorbed –...
800 lux Residential living Wohnzimmerbeleuchtung 200 lux 200 lux room lighting Straßenbeleuchtung 10 lux Street lighting 10 lux Dämmerlicht nach 1 lux Dusk after sunset 1 lux Sonnenuntergang Vollmondnacht 0,2 lux Night with full moon 0.2 lux 5.2.2 Einfluss von Abdeckungen auf Beleuchtungsstärken...
5.2.3 Abhängigkeit des Pflanzenwachstums 5.2.3 Dependence of the plant growth of the von der Beleuchtungsstärke – typische light level – typical rages Bereiche from Classification Einstufung Arrested growth, Wachstumsstillstand, < 300 < 300 plants are withering Pflanze verkümmert Kein Zuwachs 1,000 No plant growth 1.000...
Bezug zu anderen Kli mafaktoren wie Temperatur, relative Luft The recommended light intensity (PPFD) is feuchtigkeit, Düngung, Wassergabe und specified in µmol/m s. Since it is common Dosierung zu sehen sind. practice to specify the values in Lux, table 5.3.1 on page 32 lists the conversion factors...
Seite 34
Obst und Gemüse Empfohle- Lampen- Beleuch- Beleuch- ner PPFD- Pflanzensorte tungs- tungsdauer Ziel und Methode Wert in Phillips periode pro Tag µmol/m TL/HPI 16 – 18 Stun Produktion von Keim 80 – 160 ganze Jahr den (ohne Keimpflanzen in pflanzen hindurch Tageslicht) Treibhäusern...
Seite 51
Menschliches Auge Human eye Sonnenlicht Sunlight Ultraviolett Infrarot Ultraviolet Infrared PPFD µ mol/m Abb. 1 / Fig. 1: Bewertung des Lichtes nach der Wellenlänge (informative Darstellung) Ultraviolett Infrarot An assessment of light according to wavelengths Ultraviolet Infrared...
Seite 52
Reproduction of this document or its content is not allowed without permission of PRONOVA PRONOVA | Produktbereich STELZNER ® Bahnhofstraße 30 • 07639 Bad Klosterlausnitz Telefon ++49(0)3 66 01/93 49 06 Telefax ++49(0)3 66 01/93 49 07 info @ stelzner.de • www.stelzner.de 01/11...