Error Treatment

7.
Error Treatment
Message/Behaviour
Red LED flashes &
per second
Red LED is continuously lit &
non-stop
for 5 minutes,
then motor switches off.
Red LED is continuously lit &
long &
every 3 seconds repeatedly
Red LED is continuously lit &
long & 2x
every 3 seconds repeatedly
Red LED is continuously lit &
long & 4x
every 3 seconds repeatedly
Red LED is continuously lit &
long & 5x
every 3 seconds repeatedly
Red LED is continuously lit &
long & 6x
every 3 seconds repeatedly
Ersa EASY ARM 1
Cause
Filter operating time of 1500 h
expired.
Extraction arm clogged;
filter full.
Voltage too high/too low.
short
Motor blocked /
not connected /
short
defective.
System parameters corrupt.
short
Calibration parameters corrupt.
short
Filter operating time corrupt or
lost data.
short
3BA00216 • 2016-12-14 • Rev. 2
Rectification
Replace pre- and combination fil-
ter(Chapter 8) and reset filter operating
time (Chapter 6 and Figure
Switch off the device.
Examine extraction arms for foreign
objects and clean if necessary; replace
pre- and combination filter (Chapter 8).
Switch on the device and reset filter op-
erating time (Chapter 6 and Figure
Check voltage supply.
Check for blockages and remove them.
Contact Ersa Service.
Reset to factory settings (Section 6 and
Figure
).
Contact Ersa Service.
Contact Ersa Service.
Check pre- and combination filter and
replace it if necessary (Chapter 8); reset
filter operating time (Chapter 6 and
Figure
).
).
).