Connection
Observe also the operating instructions of the devices, which
are used with this product without fail (e.g. surveillance came-
ra, monitor, etc.).
• Make sure that the video signal amplifi er is de-energised.
• Connect a camera to the „VIDEO IN" plug.
• Make sure that the connected camera is supplied with power.
• Connect the display devices to the „VIDEO OUT" ports.
• Connect the low-voltage connector of the plug-in power supply included in
the delivery to the connection „DC IN".

Initial operation

• Make sure the power supply unit is connected to the video signal ampli-
fi er.
• Plug the power supply unit into a proper domestic mains socket 230V/AC
50 Hz.
• Turn your display device on and select the desired channel, if necessary.
• Use the knobs to adjust the sharpness „Sharpness", and the brightness
„Brightness", and the optimal signal reception.
The status LED „POWER" lights red, as soon as the video signal
amplifi er is supplied with operating voltage.

Maintenance and Cleaning

To clean the outside of the devices, a dry, soft and clean cloth is suffi cient.
If it is very dirty, the cloth can be moistened slightly.
Clean the housing very carefully, otherwise you may scratch it. Do not use
any aggressive cleaning agents.
Disposal
Electrical and electronic products do not belong in the
household waste!
Please dispose of the device, when it is no longer of use,
according to the current statutory requirements.
The home technology brand for the entire house. More information at www.sygonix.com

Technical Data

Video Signal Amplifi er
Operating voltage
: 12 V/DC
Video input
: Connection = 1 x BNC (75 ohms, 0.8 – 1.2 Vpp
Video output
: Connection = 2 x BNC (75 ohms, 1 Vss)
Video bandwidth
: 10Hz to 10MHz
Transmission range
: up to 1000 metres
Weight
: approx. 104 grams
Dimensions
: approx. 138 x 77 x 32mm
Operating temperature
: 0° to +55°
Storage temperature range : -20°C to +80°C
Mains adapter
Input voltage
: 230 V/DC, 50 Hz
Output voltage
: 12V/DC, 500 mA
Legal notice
These operating instructions are a publication by Sygonix GmbH, Nordring 98a, 90409 Nürnberg (www.sygonix.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming, or the capture
in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is
prohibited. These operating instructions represent the technical status at the time of printing. Changes in techno-
logy and equipment reserved. © Copyright 2011 by Sygonix GmbH.