6.ANHANG
(2) Technische Angaben zum Kabel
1. Einphasenanschluss
Etikett
Maximale
Phasenleiter
Stromstärke
No more
2 1.5mm
than 10A
2 2.5mm
10~16A
2 4mm
16 ~25A
2 6mm
25 ~32A
2 10mm
32 ~40A
2 16mm
40 ~63A
2 25mm
63~75A
2 25mm
75~101A
2 35mm
101~123A
2 50mm
123~148A
148~186A
2 70mm
186~224A
2 95mm
2. Dreiphasenanschluss
Etikett
Maximale
Phasenleiter
Stromstärke
No more
3 1.5mm
than 10A
3 2.5mm
10~16A
3 4mm
16 ~25A
3 6mm
25 ~32A
3 10mm
32 ~40A
3
40 ~63A
3
63~75A
3 25mm
75~101A
3 35mm
101~123A
3 50mm
123~148A
3 70mm
148~186A
3 95mm
186~224A
Bei Außeninstallation des Geräts sollte ein UV- beständiges Kabel verwendet werden.
Erdleitung
2
2
1.5mm
2
2
2.5mm
2
2
4mm
2
2
6 mm
2
2
10mm
2
2
16mm
2
2
mm
25
2
2
mm
25
2
2
35mm
2
2
50mm
2
2
70mm
2
2
95mm
Erdleitung
2
2
1.5mm
2
2
2.5mm
2
2
4mm
2
2
6 mm
2
2
10mm
2
2
16mm
16mm
2
2
25mm
mm
25
2
2
mm
25
2
2
35mm
2
2
50mm
2
2
70mm
2
2
95mm
Kriechstromsicherung
MCB
30mA less than 0.1 sec
20A
32A
30mA less than 0.1 sec
40A
30mA less than 0.1 sec
40A
30mA less than 0.1 sec
63A
30mA less than 0.1 sec
80A
30mA less than 0.1 sec
100A
30mA less than 0.1 sec
125A
30mA less than 0.1 sec
160A
30mA less than 0.1 sec
30mA less than 0.1 sec
225A
30mA less than 0.1 sec
250A
30mA less than 0.1 sec
280A
Kriechstromsicherung
MCB
30mA less than 0.1 sec
20A
30mA less than 0.1 sec
32A
30mA less than 0.1 sec
40A
30mA less than 0.1 sec
40A
30mA less than 0.1 sec
63A
80A
30mA less than 0.1 sec
100A
30mA less than 0.1 sec
125A
30mA less than 0.1 sec
160A
30mA less than 0.1 sec
225A
30mA less than 0.1 sec
30mA less than 0.1 sec
250A
30mA less than 0.1 sec
280A
20
Signalleiter
2
¡Á
n 0.5mm
Signalleiter
2
¡Á
n 0.5mm