Herunterladen Inhalt Inhalt Diese Seite drucken

Schiltknecht Messtechnik MiniAir20 Bedienungsanleitung Seite 40

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MiniAir20
Air Probe of stainless
steel
Measuring range Flow
Flow accuracy
Measuring range Temp.
Accuracy
Operating temperature
Head dimension
Access opening
Length of probe
Length of cable
Water Probe
Measuring range Flow
Flow accuracy of Flow
Measuring range Temp.
Accuracy
Operating temperature
Head dimension
Access opening
Length of probe
Length of cable
40
MiniAir20 Mini
up to 140° ° ° ° C Steel
0.7 - 20 m/s
0.8 - 40 m/s
1.0% fs
2.0% rdg
-20 to +140°C
+/- 0.5°C
-30 to +140°C
∅ 22 x 28 mm
35 mm
182 mm
1.5 m
MiniWater20 Micro
0.04 - 5 m/s
0.05 - 10 m/s
2.0% fs
3.5% rdg
0 to +70°C
+/- 0.5°C
-30 to +70°C
∅ 11 x 15 mm
16 mm
165 mm
5 m
MiniAir20 Mini
up to 250° ° ° ° C Steel
0.7 - 20 m/s
0.8 - 40 m/s
1.0% fs
2.0% rdg
- - - -
- - - -
-30 to +250°C
Evaluation box up to 65°C
∅ 22 x 28 mm
35 mm
182 mm
2.4 m (250°C)
1.5 m from Box
MiniWater20 Mini
0.02 - 5 m/s
0.03 - 10 m/s
2.0% fs
3.0% rdg
0 to +70°C
+/- 0.5°C
-30 to +70°C
∅ 22 x 28 mm
35 mm
175 mm
5 m
Schiltknecht Messtechnik AG

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis