Herunterladen Inhalt Inhalt Diese Seite drucken

Outline Diagram - Nibe UKVS 230 Montage- Und Betriebsanleitung

Speichertank mit rohrwärmetauscher für solarkollektor
Vorschau ausblenden Andere Handbücher für UKVS 230:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

GB
General
UKVS 230 is intended to be used for heat storage when
a smaller heat pump is docked with solar panels. It is also
possible to dock another heat source.
In the example below, NIBE SPLIT is docked to solar panels.
With NIBE Solar control the heat is spread from the solar
panels to UKVS 230 and is stored there when the sun is
shining. When there is a demand for heating the heat is
transferred via the charger pack to the heat pump and
is accessible for the house's needs. If the temperature in
UKVS 230 is sufficiently high the compressor is blocked
and the house's requirements are met by solar energy
alone.
The corrugated pipe coil has an area of 0.75 m². This is
suitable for a maximum 6 m² solar panels. The heating
time at full solar radiation is then 5 hours.
Assembly
Unscrew the water heater from the wooden pallet.
The water heater can be raised by screwing out the
length of the feet.

Outline diagram

-EP100
Abbreviations
AA25 Control unit
AA100 Relay box SRB 22
BBT24 Temp.sensor, docking
BT53 Temp.sensor, solar panel
BT54 Temp.sensor, solar coil
BT55 Temp.sensor, solar peak
CM1
Expansion vessel
4
-CM1
-EB100
-AA100
-GP31
-RM5 -GP15 -QN50
-EP30
-BT24
CM5
Expansion vessel
CP1
UKVS 230
EB100 NIBE SPLIT ACVM
EP8
Solar panel
EP30
Solar kit SCU 10
EP100 NIBE SPLIT AMS
FL4
Safety valve, solar
Dimensions
-EP30
-BT55
-CP1
-EP30
-BT54
GP4
GP15 Charge pump
GP30 Pump station SPS 10, SPS 20
GP31 Pump station MCU 10
QM4X Shut-off valve
QN50 Control valve
RMX
UKVS 230
Ø595
-EP30-BT53
-EP8
-EP30
-CM5
-AA25
-GP30
T
-RM4
T
-RM3
-FL4
-GP4
-QM44
-QM45
-QM43
Circulation pump, solar
Non-return valve
P

Werbung