(1) Device does not turn on when power switch is turned ON.
Device shut down automatically due to low battery voltage (at ~10.5V). Turn the
device OFF and start yours car's engine to recharge the car's battery. Only use this device
with the car's engine running.
Device shut down automatically to output overload. Turn the device OFF and remove
overload by unplugging high-watt devices. Electric charge should not exceed the device's
maximum continuous output power (see technical specifications).
Blown fuse Replace the fuse with standard automotive fuse of identical amperage
where applicable (see technical specifications).
(2) Device is unable to power connected equipment.
Battery running low. Low battery voltage reduces the device's power output. Turn the
device OFF and start yours car's engine to recharge the car's battery. Only use this device
with the car's engine running.
(3) Connected equipment experience audio/video distortion.
Loose connections Check and secure all connection.
Audio/Video interferences Reposition equipment antennas and the device.
Warnings & Caution
Use of the device in life support applications where failure of the device can reasonably
be expected to cause the failure of the life support equipment or to significantly affect its
safety or effectiveness is not recommended. Do not use the device in the presence of a
flammable anesthetic mixture with air, oxygen or nitrous oxide, and also not near flammable
materials, fumes or gases. Since the device requires adequate ventilation during
operation, do not block fan or cooling vents and do not cover the device. Do not operate
near car heating vents or in direct sunlight. Keep the device dry at all times and
disconnect when not in use. Turn OFF connected equipment before (!) starting your
engine. DO NOT plug a surge protector, line conditioner or UPS system into the device. If
you attach AC extension cords, use the heaviest practical gauge. Before connecting a
battery charger or adapter, check its manual to make sure that the technical specifications
of the device (including output waveform) fall within the recommendations of the external
battery charger or adapter.
Hints for Environment Protection: Packages materials are raw
materials and can be recycled. Do not disposal old devices or
batteries into the domestic waste. Cleaning: Protect the device from
contamination and pollution (use a clean drapery). Avoid using rough,
coarse-grained materials or solvents/aggressive cleaner. Wipe the
cleaned device accurately. Distributor: Technaxx Deutschland
GmbH & Co.KG, Kruppstr. 105, 60388 Frankfurt a.M., Germany