13. Setting of the times

13.1 Setting the time delay (20sec – 23min)
Set the time with the potentiometer (knob
- Turn the potentiometer clockwise → longer time,
- Trigger backwash procedure with the TESTBUTTON
13.2 Setting the backwash time (50sec – 9min)
Set the time with the potentiometer. (knob
- Turn the potentiometer clockwise → longer time,
- Trigger backwash procedure with the TESTBUTTON
13.3 Setting the rinsing time (25sec – 200sec)
Set the time with the potentiometer. (knob
- Turn the potentiometer clockwise → longer time,
- Trigger backwash procedure with the TESTBUTTON

14. Setting switch points backwash time

The switch points for backwash time are set with switch S2 on the circuit board.
4 switch points for backwashing are available
S2
OFF
ATTENTION! Prior to setting/adjusting the switch points backwashing the valve needs to
be on position "FILTER" and the Aquastar has to be turned off. (see page 10)
www.praher.com
)
1
counter clockwise → shorter time
)
2
counter clockwise → shorter time
)
3
counter clockwise → shorter time
3 days
2
7 days
14 days
GB
3
1
11