The manufacturer cannot accept responsibility for damage incurred or repairs
necessitated due to improper handling of our equipment.
Determining Optimum installation position
The location of the swimming pool heat pump is very important for efficient operation, think
about the following factors when choose the proper place:
Avoidance of air recirculation
Easy for wire and pipe connection and Water pipe line of long water lines (not
longer than 10m.) from heater to pool.
Easy for maintenance.
Drainage of condensation.
Pay attention to the following points:
1. The heat pump must be installed OUTSIDE in a well ventilated place to avoid air
recirculation or in a place with adequate area both for ventilation, installation and
maintenance. Please refer to the following illustration:
A minimum of 500mm of clearance from walls, shrubbery, equipment, etc. is required around the entire pump
circumference. This allows for ample air intake. No less than 2500mm clearance on the air outlet is required
to prevent re-circulation of air. We recommend not placing the unit underneath eaves, decks, or porches, as
this causes recirculation of discharged air, or the efficiency of the heater will be reduced or even stopped.
4
Diese Skizze stellt lediglich ein Schema bezüglich des Anschluss dar.

Elektrischer Anschluss

- Der elektrische Anschluss muss von einem konzessionerten Elektriker anhand des unten
abgebildeten Anschlussplans durchgeführt werden.
- Die Wärmepumpe muss mit der passenden Spannung betrieben werden, die am Gerät zu
finden ist.
- Die Wärmepumpe muss geerdet werden.
- Die Wärmepumpe muss mit einem Fehlerstromschutzschalter abgesichert werden.
-
Einen Schalter und elektrische Sicherung zur Unterbrechung des Stromkreises vorsehen.