Installation Instructions
Pipe Mounting Set
Promag W, L, D 400
Instruction is valid for the following assessories kit:
Order number
Device component
Kit pipe mounting
1 × mounting plate
2 × mounting part l G03 universal blue
DK5005–
3 × screw M5 × 25 torx
4 × setscrew M6 × 115
4 × nut M6 × 0,8
4 × washer spring M6
Safety instructions
• Use genuine parts from Endress+Hauser only.
• In the case of Ex-certified measuring devices: Only open in a de-
energized state (once a delay of 10 minutes has elapsed after
switching off the power supply) or in environments which do not
have a potentially explosive atmosphere.
• The measuring device is energized. Danger: Risk of electric
shock! Open the measuring device in a de-energized state only.
• Before removing the device: set the process in a safe condition
and purge the pipe of dangerous materials.
• Hot surfaces! Risk of injury! Before commencing work, allow the
system and measuring device to cool down to a touchable
temperature.
• In the case of measuring devices in custody transfer, the custody
transfer status no longer applies once the lead seal has been
removed.
• Comply with national regulations governing mounting, electrical
installation, commissioning, maintenance and repair
procedures.
• Requirements with regard to specialized technical staff for the
mounting, electrical installation, commissioning, maintenance
and repair of the measuring devices:
–trained in instrument safety
–familiar with the individual operation conditions of the devices
–for Ex-certified measuring devices: also trained in explosion
protection
• Follow the Operating Instructions for the device.
• Risk of damaging electronic components! Ensure you have a
working environment protected from electrostatic discharge.
Products
Solutions
• After removing the electronics cover, there is a risk of electric
shock as shock protection is removed! Switch off the measuring
device before removing internal covers.
• Modifications to the measuring device are not permitted.
• In the case of measuring devices in safety-related applications in
accordance with IEC 61508 or IEC 61511: After repair
recommission in accordance with Operating Instructions.
Document the repair procedure.
• Only open housing for a brief period. Avoid the penetration of
foreign bodies, moisture or contaminants.
• Replace defective seal/gaskets with genuine parts from
Endress+Hauser only.
• If threads are damaged or defective, the measuring device must
be repaired.
• Threads (e.g. of the cover for the electronics and connection
compartments) must be lubricated. Use an acid-free, non-
hardening grease if an abrasion resistant dry lubricant is non-
existent.
• If spacing is reduced or the dielectric strength of the measuring
device cannot be guaranteed during repair work, perform a test
on completion of the work (e.g. high-voltage test in accordance
with the manufacturer' s instructions).
• Service connector:
–do not connect in potentially explosive atmospheres.
–only connect to Endress+Hauser service devices.
• Observe the instructions for transporting and returning the
device outlined in the Operating Instructions.
• If you have any questions, contact your E+H service
organization.
Services
loading

Inhaltszusammenfassung für Promag D 400

  • Seite 3 Products Solutions Services EA01091D/06/A2/01.13 71237494 Einbauanleitung Rohrmontageset Promag W, L, D 400 Die Einbauanleitung ist für folgende Zubehörteile gültig: Order-Code Gerätekomponente Rohrmontageset 1 × Montageplatte 2 × Montageteil G03 universell blau DK5005– 3 × Schraube M5 × 25 Torx 4 × Gewindestift M6 × 115 4 ×...