Herunterladen Inhalt Inhalt Diese Seite drucken

Advanced Configuration - urmet domus 1083/8 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 1083/8:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38

ADVANCED CONFIGURATION

To go to advanced confi guration, put both the rotary switches on position 9.
The door unit emits an acoustic signal.
At the end of operations, put again the door unit in stand-by mode, changing the position of one of the
rotary switches at least.
CONTROL CAMERAS
If in a call module are present the control cameras, the function must be programmed.
1. Go to the advanced confi guration, by setting both the rotary switches to position 9; the door unit emits
a beep to indicate the programming state and turns the yellow led on.
2. Press the hall button (PA – CT) for the same times number as the present control cameras number. Each
time the button is pressed, the door unit emits the same beep number as the programmed cameras
number (5 max); by pressing again the button after 5 beeps, a long beep is emitted, to indicate that 0
cameras are connected (default).
3. Put again the rotary switches on the correct position to exit from the advanced confi guration.
§
If a local camera is connected to the connector "VIDEO MODULE", the call station is a video door
phone station. If no local camera is connected to the connector "VIDEO MODULE", the call station
is a door phone station. Up to 4 control cameras can be connected to the input V3/V5; the images
coming from these cameras can be displayed by users by pressing the auto-on button. If there is only
one control camera, the call station becomes a video door phone station using this camera during the
call.
BUTTON CODES
Up to 64 buttons can be connected to the door unit, using 4 expansion modules 1038/17 max.
By default the buttons are associate to the users from 0 to 63 of the column to which it belongs if the door
unit is confi gured as secondary unit.
If instead the door unit is confi gured as main unit, then the buttons are automatically associated to the
column 0, which simplifi es the installation of main units in single column systems.
EXPANSION MODULE 1038/17
Instead, if the door unit is confi gured as main unit and several columns are present in the system, an
association must be created between the buttons and the users of the different column proceed as
follows:
16
EXPANSION MODULE 1038/17
DS1083-020

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Exigo

Inhaltsverzeichnis