Important note

Please carefully read these operating instructions prior to the first
operation of the charge controller!
[ ! ]
Important notes:
·
Only connect solar modules as voltage sources – do not connect
any wind generators or other charging devices.
·
The off-load voltage Uoc of the solar system must not exceed 50V;
otherwise, the controller may be permanently damaged (see type
plate of the module).
·
A faulty or totally discharged battery (U < 8,5 V) must not be
recharged using the FOX-260 due to safety reasons.
·
All precautions regarding work with batteries and power electronics
must be observed.
·
All battery cables to the controller must be fuse-protected in
accordance to the used wire cross section, these components
are not included in the scope of supply.
·
The controller must not get in contact with water or condensing
humidity and is to be protected against direct solar radiation.
·
At the FOX-260 Li only lithium-ion batteries of type: LiFe(Y)PO4
may be connected.
·
Only use the controller in closed rooms.