INSTALLATION INSTRUCTIONS
CONFORMITY TO REGULATIONS AND LAWS
Appliances are in accordance with the EEC Directive 89/336 on the electromangetic compatibility.
WARNINGS
Installation and maintenance of the appliance and its conversion to a different gas supply must only be performed by a
qualified installer authorised by the manufacturer in compliance with current safety standards.
The manufacturer declines all responsibility for failure to comply with this requirement.
INSTALLATION
Positioning
• The overall dimensions/connections and technical data are shown on the corresponding pages in the appendix.
• Position the appliance at least 10 cm from surrounding walls.
• This distance may be reduced if the walls are flameproof or protected by insulating material.
Installation
• Carefully remove the protective film from the external panels to avoid leaving any trace of glue. Use a suitable diluent to
remove any glue residue.
• Set the appliance level by means of the adjustable feet.
Joining tables together in line
• Place the appliances side by side and adjust to the same height.
Electrical connections
• The appliance is designed to operate at the voltage indicated on the rating plate.
• Make sure the power terminal block of appliance is connected to a separate duly rated power line (see the "Technical
data" table).
• The power supply cable must be flexible and of a type matching at least the qualities of a rubber-type cable H 07 RN-F.
• The appliance must be fitted with homopolar safety cut-out switches of suitable capacity with a contact breaking distance
of at least 3 mm, and highly sensitive differential protection device. The maximum leakage current is 1 mA/kW.
Earth and equipotential connection
• Connect the equipment into an effectively earthed.
• Connect each system (PA) all electrical equipment installed
TURNING ON THE APPLIANCE
Checking the electrical system
Switch on the appliance in accordance with the instructions for use and check the control devices and heating elements.
Checking the nominal heat input
• The nominal heat input is correct when the appliance is fitted with the appropriate supply voltage is as specified in Table
T1.
GRX 1
GB
14 / 33