Herunterladen Inhalt Inhalt Diese Seite drucken

Noise Development; Technical Data - BOMANN UM 1569 CB Bedienungsanleitung

Universalmixer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
WARNING:
• Always remove the plug before cleaning.
• Under no circumstances should you immerse the device in water
for cleaning purposes. Otherwise this might result in an electric
shock or fire.
• The blades on the knife block are very sharp. A risk of injury exists!
CAUTION:
Do not use a wire brush or any abrasive items.
Do not use any acidic or abrasive detergents.
The individual parts are not dishwasher-safe.
NOTE: Preliminary Cleaning
Half fill the mixing vessel with water and turn the switch to "P"
for approximately 10 seconds. Then pour out the liquid.
For thorough cleaning, please remove the mixing vessel.
Fitting and detaching the knife block
NOTE:
The refill opening cap (measuring cup) is used as a tool here.
Use the two notches.
1. Turn the mixing vessel on its head.
2. Place the cap with the notches onto the motor block lugs.
3. With moderate force, turn the cap clockwise and release
the knife block.
4. Take the knife block carefully out of the mixing vessel.
5. Remove the seal ring for cleaning.
6. After drying, place the seal ring back onto the knife block.
7. Insert the knife block onto the thread on the bottom of the
mixing vessel. Use the notches on the knife block.
8. Using the cap as a tool, press and turn the knife block at
the same time anticlockwise (see also page 3, Fig. A).
9. Ensure that the knife block sits securely in position (see
page 3, Fig. B). The knife block lugs must sit tight on the
housing lugs.
CAUTION:
Only operate the appliance if you have properly fitted the
knife block with the seal ring! Otherwise the mixing vessel will
not be sealed.
Mixing vessel, lid, cap, knife block, and rubber seal
Clean these parts in a bowl of hot water. Then dry everything
before assembling the parts again.
Cleaning
Housing
Only a moderately moist cloth should be used for cleaning the
outside of the device.
Device is not working.
Remedy:
Check the mains connection.
Check the position of the rotary switch.
Other possible causes:
The device is fitted with a safety switch.
This prevents the motor from starting up unintentionally.
Remedy:
Check that the mixing vessel is firmly in place.

Noise development

The sound pressure level in the ear of an operator (LpA) was
measured according to DIN EN ISO 3744.
Sound pressure level detected: 76 dB(A) (no limit)
Model: ......................................................................UM 1569 CB
Power supply: .............................................. 220 - 240 V~, 50 Hz
Power rating: ...................................................................... 600 W
Protection class: ......................................................................... II
Capacity: ........................................................................max. 1.5 l
Net weight: .......................................................... approx. 3.42 kg
The right to make technical and design modifications in the
course of continuous product development remains reserved.
This device has been tested according to all relevant current
CE guidelines, such as electromagnetic compatibility and low
voltage directives, and has been constructed in accordance
with the latest safety regulations.
Troubleshooting

Technical Data

33

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis