Technical Data - Austroflamm G1 Benutzerhandbuch

Gussofen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G1

1. TECHNICAL DATA

As a stove of construction type 1, it is possible to con-
nect it to the chimney of an existing other stove or an-
other hearth for solid fuels, as long as the chimney di-
mensioning complies with DIN 4705, Part 3.
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet diameter
Nominal heat output (EN 13240)
Maximum heat capacity
Smallest heat capacity
2. IMPORTANT INFORMATION
The installation and operation information given here is
of general nature. National and European standards,
local and building regulations as well as fire prevention
laws must be observed during the operation of the
stove.
General safety instructions for the
operation of your stove
Thoroughly read the entire manual before starting up
your stove and observe the caution notices.
Your heating unit may not be moved without ap-
proved means of transport with sufficient load-bearing ca-
pacity.
Your heating unit is not suitable to be used as a stand
or as a ladder.
Please keep in mind that your
stove's surface heats up considerably
during operation. We therefore rec-
ommend wearing a safety mitten
when operating your stove.
• Attention – stove varnish is no rust prevention!
Make your children aware of this particular danger
and keep them at a distance from the heating unit when-
ever it is in operation.
Only burn approved fuels and materials listed in the
chapter "Clean Burning".
The burning or placing of flammable or explosive ma-
terials, like empty spray cans and such like into the firebox
as well as the storage of such materials in the immediate
vicinity of your heating unit is strictly forbidden due the
danger of explosion.
Do not wear loose or flammable clothing when adding
fuel to the fire.
4
Room heating capacity
(depending on building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the cal-
culation of the chimney measurements in accord-
677 mm
ance with DIN 4705, Part 2
400 mm
Fluegas mass flow
595 mm
Fluegas temperature
85 kg
Minimum feed pressure
120 mm
Nominal thermal output
6 kW
8 kW
3 kW
Placing non-heat-resistant objects on the heating unit
or in the vicinity of the heating unit is forbidden.
Do not lay laundry onto the stove for drying. Laundry
hung up to dry must be kept at a safe distance from the
stove because of the danger of fire.
The woodstove G1 is not suitable for long term heat-
ing.
During the operation of your heating unit it is forbid-
den to use flammable or explosive materials in the same
or an adjacent room to the one in which your heating unit
is located
The appliance must be operated with the stove door
closed.
The stove door and all fittings for adjusting the stove
must be closed, if the appliance is out of use.
Setting up your stove
Required safety distances
(Minimum distances – see name plate - in Fig. 2)
with protection shield or convection cladding
a > 800 mm b > 700 mm c > 400 mm
without protection shield or convection cladding
a > 800 mm b > 300 mm c > 300 mm
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly ad-
jacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the
.
stove
closed
closed
closed
at 0.8 times
n. ther. outp.
.
english
48-124 m³
5,2 g/s
330 °C
12 Pa
10 Pa
: