Herunterladen Diese Seite drucken
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Notice
for
Use:
Thank you for choosing Joyetech.
Please read this manual careful y before
use to ensure that your usage is correct.
additional information or have any questions about the product or its use, please consult your Ocal Joyetech
agent, or visit our website at www.joyetech.com
Product
Introduction:
evic Basic, being slim and cute in appearance applies
variable Temperature Contro system, supporting RTC
(Real Time Clock) display function with clock screen
protection. The evic Basic combines unique and
attractive styling with a super large OLED screen
where RTC/VW/VT/Bypass/TCR
modes can be
regulated clearly with ease. Upgradable firmware
always enables it up-to-date
Regulatory Button
evic Basic I
General
functions
How
to set
the
time
Press the fire button 3 times to enter into the setting menu. The first row will flash to
Press the left regulatory button to switch between Hour, Minute, Year, Month and Day.
Press the right regulatory button to adjust the parameter. (Note: only Year can be
reversed by pressing the eft regulatory button when adjusting). Also the eVic Basic has
two ways of time displaying: Dial Display and Numerica Display for your preference.
Switch among different
modes
Press the fire button 3 times to enter into the setting menu. Press the right regulatory button to switch among
TEMP, TCR, POWER and BYPASS modes Press the fire button to confirm
(1) Under TEMP or TCR mode, while flashing, press the left regulatory button to enter into its subsidiary
menu to set: VT, PWR, COIL and AMP. When adjusting VT, press the right regulatory button to switch
among Temp Ni, Temp Ti and Temp SS316/ MI, M2 and M3 modes Press the fire button to confirm When
the AMP row is flashing, press the right button to switch among AMP, PUFF and TIME
(2) Under POWER or BYPASS mode, while flashing, press the left regulatory button to enter into its subsidiary
menu When AMP row is flashing, press the right regulatory button to switch among AMP, PUFF and TIME
Temp-SS316
The Temp-SS316 mode is especially designed for stainless stee 316 coil We kindly recommend you Joyetech
3
evic
Basic
Material
Nickel
NiFe
Titanium
ss (303, 304, 316, 317)
Note: 1 The TCR value in the above form is 105 multiplied Of its actual value
2 The TCR value range is 1-1000
Temperature
settings
Under TEMP mode (including TCR), coil temperature can be adjusted (from 100-3150C, 200-6000F) with the
regulatory button Press right regulatory button to increase the temperature while left regulatory button to
Down it. A momentary press Of the regulatory button will increase/decrease
50C (IOOF) Long press the regulatory button will rapidly increase/decrease
Logo Mode
Press the fire button and the right regulatory button simultaneously to enter into the setting menu
Continue to press the right regulatory button for two times, and you will enter into the Logo Mode
Simply choose on/off by pressing the right regulatory button. Press the fire button to confirm
eVic Basicl
5
Should you see this message for any other reason
from recent use
press the left regulatory button so that the "base resistance" is not reset Always do remember
to choose correct operation mode to suit the coil that fitted to ensure that temperature control is accurate.
3. Wattage adjustment
under VT mode:
Maximum initial wattage can be adjusted under VT mode. Press the fire button 3 times to enter the menu
Press the left regulatory button, and the second row wil blink. Press the right regulatory button to increase
the wattage. After that, press the fire button to confirm
Note: (1) VT mode only supports a maximum of 1.5 ohm. The device will automatically switch to VW mode
when the resistance is larger than 1.5 ohm.
(2) When Kantha' Wire is applied in VT mode, the device will also automatically switch to VVV mode after
working for 2 seconds.
Malfunction
indication
and protection
Over
10 Second
Protection:
When the power button is pressed for over 10 seconds, the output will shut off and the OLED Screen WII
display "Over IOS protection"
Atomizer
Short-circuit
Protection:
When atomizer short-circuit occurs, the OLED Screen will display "Atomizer Short"
evic Basic I
7
Cautions:
1 Only have your evic Basic repaired by Joyetech
further damage to the item and/or personal injury
2 eVic Basic should be operated in dry conditions between temperatures
and charged between OC (32 'F) to 45C (1 13 •F)
3 evic Basic is designed with authentic Joyetech components. Applying evic Basic with unauthorized
components may cause the device to function improperly and/or lead to damage.
Warranty
Please consult your Joyetech product warranty card. We are not responsible for any damages caused by
human error Our warranty is not available for products purchased from third party vendors
Joyetech
agrees to provide repair under warranty pursuant
1 This warranty provides repair free Of charge for defective Joyetech brand merchandise
90 days from date of purchase by the end user.
2 This warranty may be void as a result of any of the fol owing conditions:
* Customer does not provide warranty card and original receipt Of purchase
* Merchandise failure or damage is caused due to improper use or unauthorized repair
* Merchandise failure or damage as a result of excessive force such as dropping
* Merchandise failure Or damage as a result Of usage outside Of recommended operating conditions (see
evic Basic I
9
If you require
510 Thread
and
Spring connector
Fire
Button
OLED Screen
Micro use
port
PWR40.0
COILO.SO Q
TCR Value Range
600-700
300-400
300-400
80-200
the temperature by increments Of
the temperature setting
especially when reinstalling the same coil that is still warm
DO NOT attempt to repair it on your Own as it may lead to
of -IOC (14 F ) to 60C (140 F )
to the following
terms and conditions:
Warranty period is
How
to use:
1. Power
on/off:
any
Press the fire button 5 times in quick succession, the screen will on. Then it's ready to use. In the same way,
the device wil be turned off by pressing another 5 times in quick succession
2. Vaping: Hold the fire button and inhale through the mouthpiece. Release the fire button and exhale. (Note:
Please adjust the wattage to a proper range according to your atomizer before use )
3. Charging
& Upgrading
Simply connect the device with a micro USB cable to charge or upgrade When it's fully charged, the display
will go out.
4. Set screen protection
time
When the device is on, simultaneously hold the fire button and the right regulatory button (on the
bottom) to enter into adjustment interface. Press the right regulatory button again to enter into
screen protection time setting. Choose the protection time and press the fire button to confirm
5. Reset
Should you get stuck while upgrading, just press the "+" button and then insert into the reset ho e (on the
bottom) with a needle to restart
BF-SS316
atomizer
head
TCR (MI, M2, M3)
With the TCR (Temperature Coefficient of Resistance) function available on the evic Basic, you
can customize your temperature control coils (Nit Ti, SS) on your won
Under TCR mode, when the mode indication is still flashing, press the eft regulatory button and
the sub-menu items (MI, M2, M3) will flash. Press the right regulatory button when it still flashing
to switch among MI, M2 and M3_ Press the fire button to confirm
How
to set
the
TCR?
In power-off condition, press the fire button and the right regulator simultaneously for about 5
seconds
to enter
into
the TCR
1.Press right/left regulator to choose between T CR MI , M2 or M3;
2 Then press the fire button to select certain parameter;
3.Press the regulator to set the parameter;
4.Long press the fire button or leave it for about 10 seconds to confirm
Here's the TCR Value Range for your reference
Supplementary
functions
1. Lock/unlock
the atomizer
Press the fire button three times to enter into the menu. Then press the eft regulatory button 2 times, and the
second row where the resistance display will blink. Press the right regulatory button to lock or unlock the coil
resistance When the Ock sign displayed, thus the resistance is Ocked
Note: (1) Please lock the resistance only when the coil is used at room temperature. This WII lock the correct
"base resistance" of the atomizer. Temperature control will remain accurate, as long as the coil is not
changed
Once the resistance is locked, you can remove the tank while the coils are hot Or cold and it wil
function under the same parameter.
(2) Please unlock the resistance before you change to a different atomizer or temperature control will not
work correctly
When the resistance is unlocked, please ensure any new coil is installed at room temperature
when first used to retain temperature accuracy
2. New coil, same coil
When replacing the atomizer, whose resistance is larger than the previous one to some degree,
LOGO
resetting of the atomizer "base resistance" may be required —this is the resistance of the atomizer
on
coil when it is used at room temperature
Off
When the tank is detached, press the power button to initiate a reset. After fitting a new atomizer
head and reinstall the tank, "New Coil, Same Coil" message with the ohm reading will appear on
the display Press the right regulatory button to confirm that a new coil has been fitted
Weak Battery Alert: In VT/VW mode, when the device installed with an atomizer is working and
the voltage of battery is below 2 9V, the device shows: Weak Battery Meanwhile, the output
power will be reduced accordingly.
Low
Power
Alert:
When the vo tage of battery is below 3 3V, the device shows: Battery Low
the fire button, the device shows: Battery low lock, and cannot work. Please recharge the battery
to reactivate
Unlocking Battery Low: As soon as charging has commenced low-voltage protection will be unlocked.
Atomizer
Low
Alert:
When
the
resistance
of atomizer
mode, the OLED screen wil display 'Atomizer Low"
Temperature
Protection:
In VT mode, if the actual temperature of coil is higher than the set
temperature, the device shows: "Protection"
Temperature
Alert: If the temperature of device is over 70 C , the output will shut off automatically
and the screen wil display "Device Too Hot"
precautions in usage manual)
* Merchandise failure Or damage caused by improper use Ofwater Or Other liquid (see usage manual for
operating instructions)
Merchandise failure or damage due to usage with non-Joyetech components (charger, battery, and power cable).
3. This warranty does not cover personal items or consumab e goods and attachments, including but not
limited to: mouthpiece, cartridge, atomizer head, lanyard, and leather sheath.
4. This warranty does not cover any non-Joyetech
Joyetech brand products during the warranty period of 90 days after date of purchase as indicated on proof
Of purchase
Joyetech
reserves
the right of final decision
Joyetech
may interpret
and revise the content Of this warranty terms.
Warning
1 Keep Out Of reach Of children
2. This product is NOT recommended for use by young people or non-smokers
3. This product is NOT suitable for use by child, pregnant or breast-feeding women, people who're
allergic/sensitive
to nicotine
set
menu:
as follows:
resistance
under
VT mode:
f you continue to press
is lower
than
O. Iohm
in VW
mode
or lower
brand products. This warranty is only valid for eligible
in all warranty cases.
Screen
M in
2
Min
S
M in
10
M In
IS
in
20
Min
30
M in
I evic Basic
2
TCR
MI
40.0
0.40
Q
00.0
TCR
Set
0120
M2
0120
M3
0120
I evic Basic
4
Newcoil
O.2SQ
Right
Same
Co il
O_2DQ
Left
6 | eVic Basic
6
POWER
24.ow
4.5S
COIL O.SOQ
AMP 06.94
Weak
Atomizer
Low
than
0.050hm
in VT
T EMP TI
P
t ion
400
w
COIL0.40
Q
000
P.
evic
Basic
8
I evic Basic
10
loading

Inhaltszusammenfassung für Joyetech eVic Basic

  • Seite 1 Please consult your Joyetech product warranty card. We are not responsible for any damages caused by Joyetech brand products during the warranty period of 90 days after date of purchase as indicated on proof human error Our warranty is not available for products purchased from third party vendors...
  • Seite 2 3. charge Avec sa petite taille et sa forme rectangulaire, l' evic II suffit de charger I'EVIC Basic en le connectant avec un adaptateur mural ou un ordinateur via un cable Basic s' équipe du mode contröle température, et de la USB_ Quand il est completement chargée, l'écran s'éteint...
  • Seite 3 Produktbeschreibung: Die evic Basic ist eine kleine kompakte Variante und 3. Aufladen & Upgrade: Sie können Ihre evic Basic einfach über den USB Port aufladen und upgraden. 1st bietet Temperaturkontrolle, unterstützt RTC (Real Time das Gerät vol ständig aufgeladen erlischt das Display...
  • Seite 4 QC(113QF) durante Ia carga y entre -100C(140F) a 600C(1400F) mientras estå siendo utilizado de la marca Joyetech durante el periodo de garantia de 90 dias después de la fecha de compra como se indica en el comprobante 3 EI evic Basic estå diseäado con componentes auténticos de Joyetech. La aplicaciÖn de evic Basic con...
  • Seite 5 Joyetech (quali 2 L'evic Basic deve essere utilizzato in condizioni di temperature secche di -IOOC( 140F) a 600C ( 1400F) e caricatore, batteria e cavo di alimentazione)
  • Seite 6 Onv•1caHMe: KOHHeKTop 3. 3ap9öKa u 06HoeneHue npowueKu: evic Basic, being slim and cute in appearance applies 3apRAK'-1 06HOBneHV1fi npou_wawl, npocT0 n0AKnyog"Te YCTPOLiCTB0 K KOMnbi0Tepyvepe3 Ka6ens variable Temperature Contro system, supporting RTC Micro USB, AM aapRAK',1 TaKXe MOXHOncnonb30aaTb aAanTep 220B Korna ycTpohCTB0 6yAeT nonHocTb10...